Controlled Atmosophere Preservation Box

CAPB-110 /500-A
专注于包装与材料的检测技术,致力于医疗、药品、食品、包装、纺织、新材料等行业品质控制,产品广泛应用于企业、检测机构、高校与研究院所。
  • Description
  • Applications
  • Standard
  • Features
  • Parameter
  • Configuration
  • Video
  • PDF Download
    • Commodity name: Controlled Atmosophere Preservation Box

    CAPB-110 /500-A

    Function:

    This controlled atmosphere fresh-keeping chamber is designed for preservation experiments on fruits, vegetables, flowers, and seedlings. It precisely regulates concentrations of oxygen (O₂), carbon dioxide (CO₂), nitrogen (N₂), ethylene (C₂H₄), as well as temperature and humidity conditions to achieve optimal preservation effects.

     

    Features​​:

    1. Gas Component Control and Measurement​​

    • ​​Gas Regulation​​: Intelligent control and monitoring of gas concentrations (C₂H₄, CO₂, O₂) within the chamber.
    • ​​Non-Consumptive Sensors​​: High-precision non-consumptive gas sensors minimize operational costs.
    • ​​Pressure Monitoring​​: High-accuracy differential pressure gauge measures gas pressure changes and maintains internal pressure balance.
    • ​​Ozone Sterilization​​: Integrated ozone sterilization system.
    • ​​Ethylene Removal​​: Potassium permanganate-based ethylene automatic control and removal device (optional).

    ​​02. Temperature & Humidity Control​​

    • ​​Temperature Control​​: Air-jacket internal circulation system with ultra-low energy consumption.
    • ​​Regulation Mechanism​​: Unique separation structure between control chamber and sample area enables balanced temperature/humidity regulation via internal circulation (no fogging or condensation at high humidity).
    • ​​Humidity Control​​: Built-in humidification and dehumidification system without desiccant consumables (low energy consumption).
    • ​​Water Supply​​: Automatic water circulation system; no manual refilling required (periodic cleaning recommended).
    • ​​Monitoring​​: High-precision imported temperature/humidity sensors.
    • ​​LED Lighting​​: Adjustable chamber lighting (stepless dimming).

    ​​03. Data Recording​​

    • ​​Data Export​​: USB interface with secure authorization for data export.
    • ​​Touchscreen​​: Configuration and real-time monitoring via 10.3-inch automotive-grade color touchscreen.

    ​​04. Energy Efficiency & Quiet Operation​​

    • Low energy consumption design reduces operational costs.
    • Intuitive touchscreen for on-site control.
    • Low gas consumption with internal self-regulation.

    ​​05. Door Design​​

    • ​​Anti-Condensation Door​​: Tempered glass door with hollow structure ensures stable internal temperature/humidity.
    • ​​Electric Lock​​: Authorization-based unlocking to prevent unauthorized access.

    ​​06. Safety Protections​​

    • Over-temperature/over-humidity protection.
    • Water shortage alarm for humidification system.
    • Authorized access control for chamber opening.

    ​​07. After-Sales Service​​

    • One-year warranty from acceptance date; lifetime maintenance.
    • On-site validation services available.

     

    Parameters

    • Fog-free humidifier (inside chassis)
    • Semiconductor temperature controller (rear)
    • Built-in water circulation tank (inside chassis)
    • 10.3-inch automotive-grade color touchscreen
    • White + UV lamps (integrated in stainless steel chamber)
    • RS232 and USB interfaces

    Technical Specifications

    Category

    Subcategory

    Model

    CAB-110-A

    CAB-500-A

    Stainless Steel Chamber

    Volume (L, approx.)

    108

    480

    Width (A-mm)

    560

    800

    Height (B-mm)

    480

    1200

    Depth (C-mm)

    400

    500

    Standard Grates (pcs)

    2

    2

    Max Grates (pcs)

    5

    14

    Load per Grate (kg)

    25

    30

    Door

    Electric Lock

    Yes

    Door Type

    Single-door

    Double-door

    Built-in Tank

    Water Capacity (L)

    ~5 L

    Overall Unit

    Width (D-mm)

    780

    1020

    Height (B-mm)

    990

    1730

    Depth with Handle (F-mm)

    796

    870

    Placement

    Wheeled, anchorable

    Net Weight (kg)

    ~165

    ~235

    Key Metrics

    Power Consumption(W)

    <500W

    Gas Measurement Range

    C2H4:0~220ppm(other optional),O2 :0%~25%(0~100% optional);CO2:0%~100%;other is N2

    Gas Measurement Accuracy

    C2H4:0.1 ppm; O2:0.01%;CO2:0.01%

    Gas Flow Rate

    0~500 ml/min

    Chamber Pressure Accuracy

    <5 Pa

    Temperature Range

    -5 ~ +50 ℃

    Humidity Range

    10~90% RH  (≥90% requires ICH software)

    Humidity Accuracy

    1% RH  

    Airflow Control

    0~100%  adjustable  

    Power Supply

    AC220/110V, 50/60 HZ

    LED Lighting

    White Light Intensity

    0~10,000 Lux (0~100% stepless)

    UV Spectrum

    320~400 nm

     

     

     

    Standard Configuration​

    Item

    Quantity

    Remarks

    Main Unit

    1

    Includes: Fog-free humidity system, semiconductor temperature control, internal airflow system, USB/RS232 interfaces, calibration port (Ø50mm), high-precision sensors (temperature, humidity, O₂, CO₂, C₂H₄, differential pressure), touchscreen, LED lights (white/UV), stainless steel chamber, auto-cleaning water tank, anti-condensation door, electric lock.

    Control Software

    1 set

    Touchscreen configuration and monitoring.

    USB Drive

    1

     

    Stainless Steel Grates

    2

     

    Tubing Kit

    1 set

     

    User Manual

    1 copy

     

    Factory Certificate

    1 copy

     

    Quality Certificate

    1 copy

     

     

     

    Optional Accessories​

    Item

    Quantity

    Remarks

    Ethernet Module

    1 set

     

    Professional Software

    1 set

    FDA 21 CFR Part 11/GMP compliant; supports remote/multi-device management.

    WiFi Module

    1 set

    Remote management via dedicated software/app.

    Mobile App

    1 set

    Remote/multi-device management.

    RS232 Cable

    1

     

    Computer

    1 set

     

    Calibration Certificate

    1 copy

    Third-party metrology certification.

    Standard Grates

    -

    Customizable for chamber dimensions.

    Ethylene Removal Kit

    1 set

    Optional (auto-control and adsorption).

     

  • Function

    This controlled atmosphere fresh-keeping chamber is designed for preservation experiments on fruits, vegetables, flowers, and seedlings. It precisely regulates concentrations of oxygen (O₂), carbon dioxide (CO₂), nitrogen (N₂), ethylene (C₂H₄), as well as temperature and humidity conditions to achieve optimal preservation effects.

     

  • Features​​

    1. Gas Component Control and Measurement​​

    • ​​Gas Regulation​​: Intelligent control and monitoring of gas concentrations (C₂H₄, CO₂, O₂) within the chamber.
    • ​​Non-Consumptive Sensors​​: High-precision non-consumptive gas sensors minimize operational costs.
    • ​​Pressure Monitoring​​: High-accuracy differential pressure gauge measures gas pressure changes and maintains internal pressure balance.
    • ​​Ozone Sterilization​​: Integrated ozone sterilization system.
    • ​​Ethylene Removal​​: Potassium permanganate-based ethylene automatic control and removal device (optional).

    ​​02. Temperature & Humidity Control​​

    • ​​Temperature Control​​: Air-jacket internal circulation system with ultra-low energy consumption.
    • ​​Regulation Mechanism​​: Unique separation structure between control chamber and sample area enables balanced temperature/humidity regulation via internal circulation (no fogging or condensation at high humidity).
    • ​​Humidity Control​​: Built-in humidification and dehumidification system without desiccant consumables (low energy consumption).
    • ​​Water Supply​​: Automatic water circulation system; no manual refilling required (periodic cleaning recommended).
    • ​​Monitoring​​: High-precision imported temperature/humidity sensors.
    • ​​LED Lighting​​: Adjustable chamber lighting (stepless dimming).

    ​​03. Data Recording​​

    • ​​Data Export​​: USB interface with secure authorization for data export.
    • ​​Touchscreen​​: Configuration and real-time monitoring via 10.3-inch automotive-grade color touchscreen.

    ​​04. Energy Efficiency & Quiet Operation​​

    • Low energy consumption design reduces operational costs.
    • Intuitive touchscreen for on-site control.
    • Low gas consumption with internal self-regulation.

    ​​05. Door Design​​

    • ​​Anti-Condensation Door​​: Tempered glass door with hollow structure ensures stable internal temperature/humidity.
    • ​​Electric Lock​​: Authorization-based unlocking to prevent unauthorized access.

    ​​06. Safety Protections​​

    • Over-temperature/over-humidity protection.
    • Water shortage alarm for humidification system.
    • Authorized access control for chamber opening.

    ​​07. After-Sales Service​​

    • One-year warranty from acceptance date; lifetime maintenance.
    • On-site validation services available.

     

  • Parameters

    • Fog-free humidifier (inside chassis)
    • Semiconductor temperature controller (rear)
    • Built-in water circulation tank (inside chassis)
    • 10.3-inch automotive-grade color touchscreen
    • White + UV lamps (integrated in stainless steel chamber)
    • RS232 and USB interfaces

    型号/尺寸/关键指标

    Category

    Subcategory

    Model

    CAB-110-A

    CAB-500-A

    Stainless Steel Chamber

    Volume (L, approx.)

    108

    480

    Width (A-mm)

    560

    800

    Height (B-mm)

    480

    1200

    Depth (C-mm)

    400

    500

    Standard Grates (pcs)

    2

    2

    Max Grates (pcs)

    5

    14

    Load per Grate (kg)

    25

    30

    Door

    Electric Lock

    Yes

    Door Type

    Single-door

    Double-door

    Built-in Tank

    Water Capacity (L)

    ~5 L

    Overall Unit

    Width (D-mm)

    780

    1020

    Height (B-mm)

    990

    1730

    Depth with Handle (F-mm)

    796

    870

    Placement

    Wheeled, anchorable

    Net Weight (kg)

    ~165

    ~235

    Key Metrics

    Power Consumption(W)

    <500W

    Gas Measurement Range

    C2H4:0~220ppm(other optional);O2 :0%~25%(0~100% optional);CO2:0%~100%;other is N2

    Gas Measurement Accuracy

    C2H4:0.1 ppm; O2:0.01%;CO2:0.01%

    Gas Flow Rate

    0~500 ml/min

    Chamber Pressure Accuracy

    <5 Pa

    Temperature Range

    -5 ~ +50 ℃

    Humidity Range

    10~90% RH  (≥90% requires ICH software)

    Humidity Accuracy

    1% RH  

    Airflow Control

    0~100%  adjustable  

    Power Supply

    AC220/115V,50/60 HZ

     

    LED Lighting

    White Light Intensity

    0~10,000 Lux (0~100% stepless)

    UV Spectrum

    320~400 nm

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

  • Standard Configuration​

    Item

    Quantity

    Remarks

    Main Unit

    1

    Includes: Fog-free humidity system, semiconductor temperature control, internal airflow system, USB/RS232 interfaces, calibration port (Ø50mm), high-precision sensors (temperature, humidity, O₂, CO₂, C₂H₄, differential pressure), touchscreen, LED lights (white/UV), stainless steel chamber, auto-cleaning water tank, anti-condensation door, electric lock.

    Control Software

    1 set

    Touchscreen configuration and monitoring.

    USB Drive

    1

     

    Stainless Steel Grates

    2

     

    Tubing Kit

    1 set

     

    User Manual

    1 copy

     

    Factory Certificate

    1 copy

     

    Quality Certificate

    1 copy

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

Keywords:


Previous page

Next page


Related Products


Constant Weight Determinating Analyzer of Residue after Evaporation on Water Bath

Tester of Residue after Evaporation can test the dissolving-out amount of test sample soaked in specified liquid

Water Vapor Transmission Rate (WVTR) Tester-Cup Method

W-B-121-G WVTR tester for films, packaging & building materials. ASTM E96 & ISO 2528 compliant. 0.05 g/m²·24h accuracy, fog-free humidification, 12 stations.

Ignition Residue and Ash Constant Weight Analyzer

Model No.: IRT-121 /161 /191/321 -A

Product Inquiry


Contact Us

Guangzhou Labstone Technology Co., Ltd
Add: Rm601, bldg A1, No. 2-6, Jinbao Rd, Baiyunhu Subdist., Baiyun District, Guangzhou,510430, Guangdong Province, P.R.China
Switchboard:+86(20)86406230  Technical:+86(20)86406337
 WhatsApp & Wechat:+86-13825027743
Email:market@labstone.cn 

Leave a Message to us

%{tishi_zhanwei}%

Copyright ©2026 Labstone Technology Co., Ltd  

business license