Key: test item, instrument name, total nonvolatile migration, gravimeter, moisture permeameter

%{tishi_zhanwei}%
undefined
undefined
+
  • undefined
  • undefined

Ignition Residue and Ash Constant Weight Analyzer

Model No.: IRT-121 /161 /191/321 -A
Focusing on packaging and material testing technology, we are committed to quality control in industries such as healthcare, pharmaceuticals, food, packaging, textiles, and new materials. Our products are widely used in enterprises, testing institutions, universities, and research institutes.
  • Description
  • Applications
  • Standard
  • Features
  • Parameter
  • Configuration
  • Video
  • PDF Download
    • Commodity name: Ignition Residue and Ash Constant Weight Analyzer

    Model No.: IRT-121 /161 /191/321 -A

    Function:

    Loss on drying, total ash (total solids), ignition residue, acid - insoluble ash, volatile matter, etc.

    It can replace muffle furnaces, drying ovens and balances to achieve constant weight.

    Conforming to Standards:

    • General Provisions of Constant Weight in Pharmacopoeia; "Determination of Ignition Residue" and "Determination of Ash" in Part IV of Pharmacopoeia
    • "Determination of Loss on Drying" in Pharmacopoeia; "Gravimetric Method" in ASTM and ISO Standards
    • ASTM D7348, ASTM E2403, USP-281, USP-733, Ph. Eur.-2.4.14, JP-2.44
    • GB 5009.4、GB18484、GB18485、GB/T 3780.10、GB/T 2295、GB/T 742 、GB/T 4498.1 、
    • GB/T 4498.2、GB/T 508、GB/T7531、GB/T14837、GB/T9741、GB/T4324 、GB/T 23951、
    • GB/T 31984、GB/T 6438 、YBT5082、HJ761、HJ1024、CJJ/T221、C JJ90、YC/T 427等。

    Working Principle:


    Ignition, drying, and constant - temperature weighing.

     

     

    Features

    • Process: Complies with national and industry standard processes, enable fully automated drying and ignition for constant weight determination.
    • Precision/High - efficiency: Achieves constant weight with an accuracy of 0.3mg, available with 12, 16,19 or 32 workstations.
    • Integrated Design: The drying chamber, ignition chamber, cooling chamber and balance unit are integrated into one tester, footprint reduction. 
    • Fully Automated and Digitalized: Features stepped temperature increase and full-automatic control.
    • Balance Protection: Utilizes patented isolation technology for heat, moisture, corrosion, and fire protection of the balance, ensuring its stability and service life.
    • Safety: Equipped with anti - combustion and anti - explosion functions, and power - off in case of over - temperature.
    • Software: Provides graphical, full - process, and all - element monitoring, along with multiple report formats.
    • Optional: GMP "Computerized System" functional module.
    • Optional: Sulfuric acid filling device.

     

    Technical Specifications

    Model

    IRT-121-A

    IRT-161-A 

    IRT-191-A

    ITR-321-A

    Numbers of Samples

    12

    16

    19

    32

    Numbers of Balances

    1

    Crucible Capacity

    10mL(Other custom - made available)

    Constant Weight Error

    0.3 mg

    Weighing Range

    210 g (METTLER TOLEDO)

    Balance Readability

    0.1 mg

    Residue Mass

    0.1 mg ~ 50 g

    Temperature Range

    (Room temperature ~1000)oC

    Weighing Temperature

    (Room temperature ~100)oC

    Temp.Control Accuracy

    (Room temperature ~150)oC±0.5oC;(150~1000)oC±2 oC;

    Heating Rate

    (0-30)oC /min;

    Cooling Method

    Water - cooled

    Ventilation Atmosphere

    compressed air, Inert gas 

    Gas Source Pressure

    >0.3 MPa

    Interface Size

    Φ8 mm

    Dimensions

    72(L)*90(B)*100(H) cm

    Power Supply

    AC220V /110V ;50/60Hz 

    Power

    ≤6000W

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    System Configuration

    Main unit, quartz crucibles (quantity corresponding to the number of cavities), professional testing software, gas/water pipes.

    Optional Accessories

    Corundum crucibles, ceramic crucibles,quartz crucibles, sulfuric acid filling device.

    Items to be Prepared by User

    Testing computer, compressed air, inert gas cylinder, acid/alkali, pure water source.

     

  • Functions

    Loss on drying, total ash (total solids), ignition residue, acid - insoluble ash, volatile matter, etc.

    It can replace muffle furnaces, drying ovens and balances to achieve constant weight.

  • Compliance Standards

    • General Provisions of Constant Weight in Pharmacopoeia; "Determination of Ignition Residue" and "Determination of Ash" in Part IV of Pharmacopoeia
    • "Determination of Loss on Drying" in Pharmacopoeia; "Gravimetric Method" in ASTM and ISO Standards
    • GB 5009.4、GB18484、GB18485、GB/T 3780.10、GB/T 2295、GB/T 742 、GB/T 4498.1 、
    • GB/T 4498.2、GB/T 508、GB/T7531、GB/T14837、GB/T9741、GB/T4324 、GB/T 23951、
    • GB/T 31984、GB/T 6438 、YBT5082、HJ761、HJ1024、CJJ/T221、C JJ90、YC/T 427等。
  • Features

    • Process: Complies with national and industry standard processes, enable fully automated drying and ignition for constant weight determination.
    • Precision/High - efficiency: Achieves constant weight with an accuracy of 0.3mg, available with 12,16,19 or 32 workstations.
    • Integrated Design: The drying chamber, ignition chamber, cooling chamber and balance unit are integrated into one tester, footprint reduction. 
    • Fully Automated and Digitalized: Features stepped temperature increase and full-automatic control.
    • Balance Protection: Utilizes patented isolation technology for heat, moisture, corrosion, and fire protection of the balance, ensuring its stability and service life.
    • Safety: Equipped with anti - combustion and anti - explosion functions, and power - off in case of over - temperature.
    • Software: Provides graphical, full - process, and all - element monitoring, along with multiple report formats.
    • Optional: GMP "Computerized System" functional module.
    • Optional: Sulfuric acid filling device.
  • Technical Specifications

    Model

    IRT-81-A

    IRT-121-A 

    IRT-161-A

    Numbers of Samples

    8

    12

    16

    Numbers of Balances

    1

    Crucible Capacity

    10mL(Other custom - made available)

    Constant Weight Error

    0.3 mg

    Weighing Range

    210 g (METTLER TOLEDO)

    Balance Division

    0.1 mg

    Residue Mass

    0.1 mg~50g

    Temperature Range

    (Room temperature ~1000)℃

    Weighing Temperature

    (Room temperature ~100)℃

    Temperature Control Accuracy

    (Room temperature ~150)℃±0.5 ℃;(150~1000)℃±2 ℃;

    Heating Rate

    (0-30)℃/min;

    Cooling Method

    Water - cooled

    Ventilation Atmosphere

    compressed air, Inert gas 

    Gas Source Pressure

    >0.3 MPa

    Interface Size

    Φ8 mm

    Dimensions

    72(L)*90(B)*100(H) cm

    72(L)*90(B)*100(H) cm

    72(L)*90(B)*100(H) cm

    Power Supply

    AC220V /110V ;50/60Hz 

    Power

    ≤6000W

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

  • Standard Configuration

    Main unit, quartz crucibles (quantity corresponding to the number of cavities), professional testing software, gas/water pipes.

    Optional Accessories

    Corundum crucibles, ceramic crucibles,quartz crucibles, sulfuric acid filling device.

    Items to be Prepared by User

    Testing computer, compressed air, inert gas cylinder, acid/alkali, pure water source.

Keywords:



Related Products


undefined

undefined

Product Consultation


Contact Us

Guangzhou Labstone Technology Co., Ltd
Add: Rm601, bldg A1, No. 2-6, Jinbao Rd, Baiyunhu Subdist., Baiyun District, Guangzhou,510430, Guangdong Province, P.R.China
Switchboard:+86(20)86406230  Technical:+86(20)86406337
 WhatsApp & Wechat:+86-13825027743
Email:market@labstone.cn 

Leave a Message to us

%{tishi_zhanwei}%

Copyright ©2026 Labstone Technology Co., Ltd  

business license