IRT-292 /362 -A
Integrated Dryer‑Ashing‑Weighing Workstation for Ignition Residue, Loss on Ignition & Ash Content
---IRT Series (Constant‑Weight Determination System)
Overview
The LabStone IRT Series Integrated Dryer‑Ashing‑Weighing Workstation is a professional laboratory system engineered specifically for ignition residue, loss on ignition (LOI), total ash, acid‑insoluble ash, and volatile matter determination.Unlike conventional workflows that rely on separate muffle furnaces, drying ovens, desiccators, and manual weighing, the IRT Series integrates low‑temperature drying, high‑temperature ashing (up to 1000°C), controlled cooling, and precision weighing into a single, fully automated platform.It is the instrument of choice for pharmaceutical QC, food and feed analysis, environmental solid waste testing, and chemical / materials characterization, wherever gravimetric ash and residue methods are required.Core Applications
1. Ignition Residue & Loss on Ignition (LOI)
Determination of ignition residue and loss on ignition in pharmaceuticals, chemicals, polymers, and inorganic materials.Fully compliant with Chinese Pharmacopoeia (ChP) requirements for residue on ignition and sulfated ash.Automatic execution of the constant‑weight cycle (successive weighing difference ≤ 0.3mg).2. Total Ash & Acid‑Insoluble Ash
Total ash determination in food, feed, cereals, starch, and plant‑derived materials.Acid‑insoluble ash testing with optional sulfuric acid filling device to minimize operator exposure.Applicable to coal, coke, carbon black, catalysts, and minerals.3. Volatile Matter & Fixed Carbon
Volatile matter and fixed carbon analysis in coal, coke, carbonaceous materials, and biomass.High‑temperature ashing with programmable ramp rates and inert‑gas atmosphere control.Working Principle
Drying / Pre‑treatment: Samples are dried at controlled low temperature (≤ 150°C) to remove moisture.High‑Temperature Ashing: Samples are transferred to the high‑temperature chamber (up to 1000°C) for complete combustion of organic matter.Controlled Cooling: After ignition, crucibles are cooled in a water‑cooled chamber under a controlled atmosphere (compressed air or inert gas).Precision Weighing: A METTLER TOLEDO analytical balance (0.1mg readability) performs automatic weighing.Constant‑Weight Cycle: The system repeats drying / ignition / cooling / weighing until the constant‑weight criterion (≤ 0.3mg) is satisfied, then calculates and reports results.
Compliance Standards
ASTM Gravimetric Ash MethodsISO Ash and Residue Determination StandardsChP General Provisions: Constant‑weight definition and ignition residue methodsGB 5009.4 - Determination of ash in foodsGB/T 6438 - Determination of crude ash in feedsYC/T 427 - Determination of ash in tobacco and tobacco productsGB 18484 / GB 18485 - Determination of ash and loss on ignition in solid wasteHJ 761 / HJ 1024 - Ash content of solid waste and sludgeCJJ/T 221 / CJJ 90 - Municipal solid waste analysisGB/T 3780.10 - Carbon black - Ash contentGB/T 2295 / GB/T 7528 - Carbonaceous materials - Ash and volatile matterGB/T 508 / GB/T 7531 - Petroleum products and synthetic resins - Ash / ignition residueGB/T 9741 / GB/T 14837 - Chemical reagents and polymers - Ignition residueGB/T 4324 / GB/T 23951 - Metals and inorganic compounds - Ash / LOIGB/T 31984 - Industrial solid waste - Ash contentYB/T 5082 - Coke - Ash contentKey Features
Dual‑Zone Thermal Control: Integrated low‑temperature drying (≤ 150 °C) and high‑temperature ashing (up to 1000 °C) in one system.Fully Automated Constant‑Weight: Automates the complete “dry / ignite / cool / weigh” cycle until ≤ 0.3 mg stability is achieved.High Throughput: Up to 36 samples per run with dual‑balance configuration (IRT‑362‑A), ideal for contract laboratories and high‑volume QC.Patented Balance Protection: Thermal isolation, moisture‑proofing, corrosion resistance, and fire‑retardant design safeguard the METTLER TOLEDO balance.Safe Operation: Anti‑combustion and anti‑explosion design, over‑temperature power cut‑off, and programmable atmosphere control.Water‑Cooled Cooling: Rapid, stable cooling of crucibles, minimizing moisture reabsorption and improving repeatability.GMP‑Ready (Optional): Optional Computerized System Module with user management, electronic signatures, and audit trails for regulated environments.Optional Sulfuric Acid Filling: Automated sulfuric acid addition for acid‑insoluble ash testing, enhancing operator safety.Technical Specifications
Model
IRT-292-A
IRT-362-A
Numbers of Samples
29
36
Numbers of Balances
2
Crucible Capacity
10mL(Other custom - made available)
Constant Weight Error
0.3 mg
Weighing Range
220g (METTLER TOLEDO)
Balance Readability
0.1 mg
Residue Mass
0.1 mg~50g
Temp. Range
RT to 1000℃
Weighing Temperature
RT to 100℃
Temp. Control Accuracy
(RT to 150)±0.5 ℃;(150 to 1000)±2 ℃;
Heating Rate
(0-30)℃/min;
Cooling Method
Water - cooled
Ventilation Atmosphere
compressed air, Inert gas
Gas Source Pressure
>0.3 MPa
Interface Size
Φ8 mm
Dimensions
72(L)*90(B)*100(H) cm
Power Supply
AC220V /110V ;50/60Hz
Power
≤6000W
Standard Configuration
Main testing unit (host)Quartz crucibles (quantity matching model capacity)Professional testing softwareGas and water connection tubingOptional Accessories
GMP Computerized System ModuleSulfuric Acid Filling DeviceCorundum cruciblesCeramic cruciblesAdditional quartz cruciblesUser‑Provided Items
Testing computerCompressed air source (> 0.3 MPa)Inert gas cylinder (if required)Acids / alkalisPure water sourceApplication Industries & Scenarios
Pharmaceutical & Health Products
- Ignition residue / sulfated ash (ChP, USP, EP)
- Herbal extracts and API intermediates
- Stability studies involving ash and residue profiling
Food, Feed & Agriculture
- Total ash and acid‑insoluble ash in cereals, flour, starch, and animal feed
- Tobacco ash analysis (YC/T 427)
- Plant‑based materials and nutraceuticals
Environmental & Waste Management
- Municipal solid waste, sludge, and incinerator residues
- Soil and sediment ash content
- Hazardous waste characterization
Chemicals, Petrochemicals & Materials
- Polymers and resins (GB/T 9741, GB/T 14837)
- Carbon black, coke, graphite (GB/T 3780.10, YB/T 5082)
- Catalysts, inorganic salts, and specialty chemicals
Frequently Asked Questions (FAQ)
Q1: What is the difference between the IRT Series and a conventional muffle furnace?A: A muffle furnace only provides high‑temperature ashing. After ignition, samples must be manually transferred to a desiccator and weighed-an error‑prone process. The IRT Series integrates drying, ashing, cooling, and weighing in one closed system, automating the entire constant‑weight procedure and eliminating manual handling.Q2: Why is the “≤ 0.3 mg constant‑weight” feature important?A: Pharmacopoeia and many national standards define constant weight as successive weighings differing by no more than 0.3 mg. Manual achievement of this criterion is tedious and inconsistent. The IRT automates it entirely, ensuring compliance and repeatability.Q3: Can the IRT Series perform acid‑insoluble ash testing?A: Yes. With the optional sulfuric acid filling device, the instrument can automatically add sulfuric acid prior to ashing, greatly improving operator safety and method consistency.Q4: Which crucible material should I choose?A: Quartz is standard for most applications due to its chemical inertness and thermal shock resistance. Corundum (alumina) or ceramic crucibles are recommended for strongly alkaline fluxes or aggressive acids.Q5: Is the instrument suitable for volatile or explosive samples?A: Yes. The system supports inert‑gas purging and features anti‑combustion / anti‑explosion safeguards, making it suitable for controlled ignition of potentially hazardous materials. -
Functions
Loss on drying, total ash (total solids), ignition residue, acid - insoluble ash, volatile matter, etc.
It can replace muffle furnaces, drying ovens and balances to achieve constant weight.
Principle
Ignition, drying, and constant - temperature weighing. -
Compliance Standards
- General Provisions of Constant Weight in Pharmacopoeia; "Determination of Ignition Residue" and "Determination of Ash" in Part IV of Pharmacopoeia
- "Determination of Loss on Drying" in Pharmacopoeia; "Gravimetric Method" in ASTM and ISO Standards
- GB 5009.4、GB18484、GB18485、GB/T 3780.10、GB/T 2295、GB/T 742 、GB/T 4498.1 、
- GB/T 4498.2、GB/T 508、GB/T7531、GB/T14837、GB/T9741、GB/T4324 、GB/T 23951、
- GB/T 31984、GB/T 6438 、YBT5082、HJ761、HJ1024、CJJ/T221、C JJ90、YC/T 427等。
- General Provisions of Constant Weight in Pharmacopoeia; "Determination of Ignition Residue" and "Determination of Ash" in Part IV of Pharmacopoeia
-
Features
- Process: Complies with national and industry standard processes, enable fully automated drying and ignition for constant weight determination.
- Precision/High - efficiency: Achieves constant weight with an accuracy of 0.3mg, available with 9, 13, or 19 workstations.
- Integrated Design: The drying chamber, ignition chamber, cooling chamber and balance unit are integrated into one tester, footprint reduction.
- Fully Automated and Digitalized: Features stepped temperature increase and full-automatic control.
- Balance Protection: Utilizes patented isolation technology for heat, moisture, corrosion, and fire protection of the balance, ensuring its stability and service life.
- Safety: Equipped with anti - combustion and anti - explosion functions, and power - off in case of over - temperature.
- Software: Provides graphical, full - process, and all - element monitoring, along with multiple report formats.
- Optional: GMP "Computerized System" functional module.
- Optional: Sulfuric acid filling device.
- Process: Complies with national and industry standard processes, enable fully automated drying and ignition for constant weight determination.
-
Technical Specifications
Model
IRT-292-A
IRT-362-A
Numbers of Samples
29
36
Numbers of Balances
2
Crucible Capacity
10mL(Other custom - made available)
Constant Weight Error
0.3 mg
Weighing Range
210 g (METTLER TOLEDO)
Balance Division
0.1 mg
Residue Mass
0.1 mg~50g
Temperature Range
(Room temperature ~1000)℃
Weighing Temperature
(Room temperature ~100)℃
Temperature Control Accuracy
(Room temperature ~150)℃±0.5 ℃;(150~1000)℃±2 ℃;
Heating Rate
(0-30)℃/min;
Cooling Method
Water - cooled
Ventilation Atmosphere
compressed air, Inert gas
Gas Source Pressure
>0.3 MPa
Interface Size
Φ8 mm
Dimensions
72(L)*90(B)*100(H) cm
72(L)*90(B)*100(H) cm
Power Supply
AC220V /110V ;50/60Hz
Power
≤6000W
-
System Configuration
Main unit, quartz crucibles (quantity corresponding to the number of cavities), professional testing software, gas/water pipes.
Optional Accessories
Corundum crucibles, ceramic crucibles,quartz crucibles, sulfuric acid filling device.
Items to be Prepared by User
Testing computer, compressed air, inert gas cylinder, acid/alkali, pure water source.
Keywords:
Related Products
undefined
Product Consultation
Contact Us
Guangzhou Labstone Technology Co., Ltd
Add: Rm601, bldg A1, No. 2-6, Jinbao Rd, Baiyunhu Subdist., Baiyun District, Guangzhou,510430, Guangdong Province, P.R.China
Switchboard:+86(20)86406230 Technical:+86(20)86406337
WhatsApp & Wechat:+86-13825027743
Email:market@labstone.cn
Leave a Message to us
fOLLOW