Key: test item, instrument name, total nonvolatile migration, gravimeter, moisture permeameter
Product
WVTR Permeation Tester - Infrared Method
- Description
- Applications
- Standard
- Features
- Parameter
- Configuration
- Video
- PDF Download
-
- Commodity name: WVTR Permeation Tester - Infrared Method
W-IR-11-G
Function:
Water vapor permeability testing - water vapor transmission rate, permeation amount, permeation coefficient.
Used for Membranes, films, sheets, containers made of materials such as plastic, fabric, leather, metal, etc.
Principle:
Wavelength-modulated Tunable Diode Laser Absorption Spectroscopy (TDLAS) for trace water sensing. Nitrogen gas at a certain humidity flows on one side of the specimen, and dry nitrogen gas (carrier gas) flows on the other side at a fixed flow rate. The humidity difference of the sample drives water vapor to permeate from the high humidity side to the low humidity side. The permeated water vapor is carried to the infrared sensor by the flowing dry nitrogen gas (carrier gas). The sensor measures the water vapor concentration in the carrier gas. Based on the water vapor concentration in the carrier gas, parameters such as water vapor permeability of the sample are calculated.

Standards:
ASTM F1249, ISO 15106-2, TAPPI T557, JIS K7129, Chinese Pharmacopoeia (Part Four) - Method for Determination of Water Vapor Permeability, YBB 00092003, GB/T 26253.
Product Features:
- Wavelength-modulated tunable diode laser infrared micro water sensor with ultra-long optical path (20 meters) absorption and high accuracy.
- Automatic attenuation compensation: No need for regular recalibration, no continuous data decay.
- Humidity control: 35%~90% RH, fully automatic, no fog.
- Temperature control: Semiconductor cooling and heating bidirectional control, high precision, stable and reliable.
- Strong environmental adaptability: Indoor environment, temperature 10°C-30°C, no humidity requirements, low operating costs.
- Sample installation: Pneumatic clamp sample (H-type). Sample anti leakage sealing installation technology.
- Fully automatic: One-key startup, fully intelligent; data saved in case of power outage; self-check at startup to avoid testing in a faulty state.
- Software: Graphical, comprehensive, all-element monitoring; multiple report formats.
- Optional: GMP Computerized System functional module.
Technical Specifications:
Parameter
Value
Parameter
Value
Humidity Range
0%,35%~90%RH
Humidity Error
±2% RH
Temperature Range
15℃~45℃
Temperature Error
±0.3℃
Sample Thickness
<3 mm
Operating Environment
indoor:10℃~30 ℃
Carrier Gas
99.999% High Purity Nitrogen Gas
Carrier Gas Flow
0~100 or 0~300 cm3/min
Operating Pressure
0.1~0.2 MPa
Connect Size
1/8” metal tube
Power supply
AC220V /110V ;50/60Hz
Power
<1.5KW
Sample Quantity
1
Sample Area(cm2)
50.0
Film Measurement Range
0.005~100(g/m2.24h)
Film Measurement Resolution
0.001(g/m2.24h)
Container Measurement Range
0.00005~0.5(g/pkg.24h)
Container Measurement Resolution
0.00001(g/pkg.24h)
Mainframe Size
415×720×400(LxWxH) mm
Mainframe Net Weight (Kg)
50
Parameters System Configuration:
Mainframe, testing computer, professional testing software, water trap, sampler, nitrogen cylinder pressure reducing valve, sealing grease.
Optional Components:
Container testing kit, container temperature control testing kit, specimen MASK (7cm2/1cm2).
Self-supplied:
High purity nitrogen gas, distilled water.
-
Function:
Water vapor permeability testing - water vapor transmission rate, permeation amount, permeation coefficient.
Used for Membranes, films, sheets, containers made of materials such as plastic, fabric, leather, metal, etc.
Principle:
Wavelength-modulated Tunable Diode Laser Absorption Spectroscopy (TDLAS) for trace water sensing. Nitrogen gas at a certain humidity flows on one side of the specimen, and dry nitrogen gas (carrier gas) flows on the other side at a fixed flow rate. The humidity difference of the sample drives water vapor to permeate from the high humidity side to the low humidity side. The permeated water vapor is carried to the infrared sensor by the flowing dry nitrogen gas (carrier gas). The sensor measures the water vapor concentration in the carrier gas. Based on the water vapor concentration in the carrier gas, parameters such as water vapor permeability of the sample are calculated.

-
Standards:
ASTM F1249, ISO 15106-2, TAPPI T557, JIS K7129, Chinese Pharmacopoeia (Part Four) - Method for Determination of Water Vapor Permeability, YBB 00092003, GB/T 26253.
-
Product Features:
- Wavelength-modulated tunable diode laser infrared micro water sensor with ultra-long optical path (20 meters) absorption and high accuracy.
- Automatic attenuation compensation: No need for regular recalibration, no continuous data decay.
- Humidity control: 35%~90% RH, fully automatic, no fog.
- Temperature control: Semiconductor cooling and heating bidirectional control, high precision, stable and reliable.
- Strong environmental adaptability: Indoor environment, temperature 10°C-30°C, no humidity requirements, low operating costs.
- Sample installation: Pneumatic clamp sample (H-type). Sample anti leakage sealing installation technology.
- Fully automatic: One-key startup, fully intelligent; data saved in case of power outage; self-check at startup to avoid testing in a faulty state.
- Software: Graphical, comprehensive, all-element monitoring; multiple report formats.
- Optional: GMP Computerized System functional module.
- Wavelength-modulated tunable diode laser infrared micro water sensor with ultra-long optical path (20 meters) absorption and high accuracy.
-
Technical Specifications:
Parameter
Value
Parameter
Value
Humidity Range
0%,35%~90%RH
Humidity Error
±2% RH
Temperature Range
15℃~45℃
Temperature Error
±0.3℃
Sample Thickness
<3 mm
Operating Environment
indoor:10℃~30 ℃
Carrier Gas
99.999% High Purity Nitrogen Gas
Carrier Gas Flow
0~100 or 0~300 cm3/min
Operating Pressure
0.1~0.2 MPa
Connect Size
1/8” metal tube
Power supply
AC220V /110V ;50/60Hz
Power
<1.5KW
Sample Quantity
1
Sample Area(cm2)
50.0
Film Measurement Range(g/m2.24h)
0.005~100
Film Measurement Resolution(g/m2.24h)
0.001
Container Measurement Range(g/pkg.24h)
0.00005~0.5
Container Measurement Resolution(g/pkg.24h)
0.00001
Mainframe Size
(mm)
415 (L)×720(W)×400(H)
Mainframe Net Weight (Kg)
50
Parameters -
System Configuration:
Mainframe, testing computer, professional testing software, water trap, sampler, nitrogen cylinder pressure reducing valve, sealing grease.
Optional Components:
Container testing kit, container temperature control testing kit, specimen MASK (7cm2/1cm2).
Self-supplied:
High purity nitrogen gas, distilled water.
Keywords:
Related Products
undefined
Product Consultation
Contact Us
Guangzhou Labstone Technology Co., Ltd
Add: Rm601, bldg A1, No. 2-6, Jinbao Rd, Baiyunhu Subdist., Baiyun District, Guangzhou,510430, Guangdong Province, P.R.China
Switchboard:+86(20)86406230 Technical:+86(20)86406337
WhatsApp & Wechat:+86-13825027743
Email:market@labstone.cn
Leave a Message to us
fOLLOW