Key: test item, instrument name, total nonvolatile migration, gravimeter, moisture permeameter

%{tishi_zhanwei}%
undefined
undefined
+
  • undefined
  • undefined

Water Vapor Transmission Rate Analyzer - Infrared Method

W-IR-31-H
Focusing on packaging and material testing technology, we are committed to quality control in industries such as healthcare, pharmaceuticals, food, packaging, textiles, and new materials. Our products are widely used in enterprises, testing institutions, universities, and research institutes.
  • Description
  • Applications
  • Standard
  • Features
  • Parameter
  • Configuration
  • Video
  • PDF Download
    • Commodity name: Water Vapor Transmission Rate Analyzer - Infrared Method

    W-IR-31-H

    Function:

    Water vapor permeability testing - water vapor transmission rate, permeation amount, permeation coefficient.  

    Used for Membranes, films, sheets, containers made of materials such as plastic, fabric, leather, metal, etc.

     

    Principle:

    Wavelength-modulated Tunable Diode Laser Absorption Spectroscopy (TDLAS) for trace water sensing. Nitrogen gas at a certain humidity flows on one side of the specimen, and dry nitrogen gas (carrier gas) flows on the other side at a fixed flow rate. The humidity difference of the sample drives water vapor to permeate from the high humidity side to the low humidity side. The permeated water vapor is carried to the infrared sensor by the flowing dry nitrogen gas (carrier gas). The sensor measures the water vapor concentration in the carrier gas. Based on the water vapor concentration in the carrier gas, parameters such as water vapor permeability of the sample are calculated.

    Compliant Standards:

    ASTM F1249, ISO 15106-2, TAPPI T557, JIS K7129, Chinese Pharmacopoeia (Part Four) - Method for Determination of Water Vapor Permeability, YBB 00092003, GB/T 26253.

    Product Features:

    • Wavelength-modulated tunable diode laser infrared micro water sensor with ultra-long optical path (20 meters) absorption and high accuracy.
    • Automatic attenuation compensation: No need for regular recalibration, no continuous data decay.
    • Humidity control: 35%~90% RH, fully automatic, no fog.
    • Temperature control: Semiconductor cooling and heating bidirectional control, high precision, stable and reliable.
    • Strong environmental adaptability: Indoor environment, temperature 10°C-30°C, no humidity requirements, low operating costs.
    • Sample installation: Pneumatic clamp sample (H-type). Sample anti leakage sealing installation technology.
    • Fully automatic: One-key startup, fully intelligent; data saved in case of power outage; self-check at startup to avoid testing in a faulty state.
    • Software: Graphical, comprehensive, all-element monitoring; multiple report formats.
    • Optional: GMP Computerized System functional module.

    Technical Specifications:

    Parameter

    alue

    Parameter

    Value

    Humidity Range

    0%,35%~90%RH

    Humidity Error

    ±2% RH

    Temperature Range

    15℃~45℃

    Temperature Error

    ±0.3℃

    Sample Thickness

    <3 mm

    Operating Environment

    indoor:10℃ to 30 ℃

    Carrier Gas

    99.999% High Purity Nitrogen Gas

    Carrier Gas Flow

    0~100 or 0~300 cm3/min

    Operating Pressure

    0.1~0.2 MPa

    Connect Size

    1/8” metal tube

    Power supply

       AC220V /110V ;50/60Hz 

    Power

    <1.5KW

    Sample Quantity

    3

    Sample   Area(cm2)

    38.48

    Film Measure Range

    0.005~100(g/m2.24h)

    Film Measure Resolution

    0.001(g/m2.24h)

    Container Measure Range

    0.00005~0.5(g/pkg.24h)

    Container Measure Resolution

    0.00001(g/pkg.24h)

    Mainframe Size

    415×720×400mm (LxWxH)

    Mainframe Net Weight

    50 Kgs

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    System Configuration: 

    Mainframe, testing computer, professional testing software, water trap, sampler, nitrogen cylinder pressure reducing valve, sealing grease. 

    Optional Components: 

    Container testing kit, container temperature control testing kit, specimen MASK (7cm2/1cm2).

    Self-supplied: 

    High purity nitrogen gas, distilled water.

  • Function:

    Water vapor permeability testing - water vapor transmission rate, permeation amount, permeation coefficient.  

    Used for Membranes, films, sheets, containers made of materials such as plastic, fabric, leather, metal, etc.

     

    Principle:

    Wavelength-modulated Tunable Diode Laser Absorption Spectroscopy (TDLAS) for trace water sensing. Nitrogen gas at a certain humidity flows on one side of the specimen, and dry nitrogen gas (carrier gas) flows on the other side at a fixed flow rate. The humidity difference of the sample drives water vapor to permeate from the high humidity side to the low humidity side. The permeated water vapor is carried to the infrared sensor by the flowing dry nitrogen gas (carrier gas). The sensor measures the water vapor concentration in the carrier gas. Based on the water vapor concentration in the carrier gas, parameters such as water vapor permeability of the sample are calculated.

  • Standards:

    ASTM F1249, ISO 15106-2, TAPPI T557, JIS K7129, Chinese Pharmacopoeia (Part Four) - Method for Determination of Water Vapor Permeability, YBB 00092003, GB/T 26253.

  • Product Features:

    • Wavelength-modulated tunable diode laser infrared micro water sensor with ultra-long optical path (20 meters) absorption and high accuracy.
    • Automatic attenuation compensation: No need for regular recalibration, no continuous data decay.
    • Humidity control: 35%~90% RH, fully automatic, no fog.
    • Temperature control: Semiconductor cooling and heating bidirectional control, high precision, stable and reliable.
    • Strong environmental adaptability: Indoor environment, temperature 10°C-30°C, no humidity requirements, low operating costs.
    • Sample installation: Pneumatic clamp sample (H-type). Sample anti leakage sealing installation technology.
    • Fully automatic: One-key startup, fully intelligent; data saved in case of power outage; self-check at startup to avoid testing in a faulty state.
    • Software: Graphical, comprehensive, all-element monitoring; multiple report formats.
    • Optional: GMP Computerized System functional module.
  • Parameter

    Value

    Parameter

    Value

    Humidity Range

    0%,35%~90%RH

    Humidity Error

    ±2% RH

    Temperature Range

    15℃~45℃

    Temperature Error

    ±0.3℃

    Sample Thickness

    <3 mm

    Operating Environment

    indoor:10℃~30 ℃

    Carrier Gas

    99.999% High Purity Nitrogen Gas

    Carrier Gas Flow

    0~100 or 0~300 cm3/min

    Operating Pressure

    0.1~0.2 MPa

    Connect Size

    1/8” metal tube

    Power supply

       AC220V /110V ;50/60Hz 

    Power

    <1.5KW

    Sample Quantity

    3

    Sample   Area(cm2)

    38.48

    Film Measurement Range(g/m2.24h)

    0.005~100

    Film Measurement Resolution(g/m2.24h)

    0.001

    Container Measurement Range(g/pkg.24h)

    0.00005~0.5

    Container Measurement Resolution(g/pkg.24h)

    0.00001

    Mainframe Size

    (mm)

    415 (L)×720(W)×400(H)

    Mainframe Net Weight (Kg)

    50

    Parameters
  • System Configuration: 

    Mainframe, testing computer, professional testing software, water trap, sampler, nitrogen cylinder pressure reducing valve, sealing grease. 

    Optional Components: 

    Container testing kit, container temperature control testing kit, specimen MASK (7cm2/1cm2).

    Self-supplied: 

    High purity nitrogen gas, distilled water.

Keywords:



Related Products


undefined

undefined

Product Consultation


Contact Us

Guangzhou Labstone Technology Co., Ltd
Add: Rm601, bldg A1, No. 2-6, Jinbao Rd, Baiyunhu Subdist., Baiyun District, Guangzhou,510430, Guangdong Province, P.R.China
Switchboard:+86(20)86406230  Technical:+86(20)86406337
 WhatsApp & Wechat:+86-13825027743
Email:market@labstone.cn 

Leave a Message to us

%{tishi_zhanwei}%

Copyright ©2026 Labstone Technology Co., Ltd  

business license