Key: test item, instrument name, total nonvolatile migration, gravimeter, moisture permeameter

%{tishi_zhanwei}%
undefined
undefined
+
  • undefined
  • undefined

Real-time Online Dew Point Meter

DPM-16L
Focusing on packaging and material testing technology, we are committed to quality control in industries such as healthcare, pharmaceuticals, food, packaging, textiles, and new materials. Our products are widely used in enterprises, testing institutions, universities, and research institutes.
  • Description
  • Applications
  • Standard
  • Features
  • Parameter
  • Configuration
  • Video
  • PDF Download
    • Commodity name: Real-time Online Dew Point Meter

    DPM-16L

    Online Electrolytic Moisture & Dew Point Analyzer — Explosion-Proof Process Monitor

     

    Functions

    Perform continuous online measurement​ of trace moisture content and dew point in non‑corrosive, acidic, and slightly corrosive gases.
    Monitor gas drying processes in real time to prevent corrosion, hydrate formation, and product quality degradation.
    Integrate with plant DCS, SCADA, or centralized monitoring systems​ via RS‑485 Modbus communication.
    Essential for natural gas processing, petrochemical plants, hydrogen production, and specialty gas manufacturing.

     

    Working Principle

    The analyzer employs the electrolytic method​ using a phosphorus pentoxide (P₂O₅) sensor. A coil‑like double platinum wire with a gap of less than 20 µm constitutes the electrolytic cell. P₂O₅ in the gap acts as a strong desiccant, absorbing trace water from the gas stream to form phosphoric acid. When a voltage is applied across the platinum wires, the phosphoric acid undergoes electrolysis, generating a weak DC current. This current is directly proportional to the mass of water absorbed per unit time. The embedded microprocessor converts the measured current into moisture content (ppmv)​ and dew point temperature (°C Td), transmitting both values in real time via RS‑485.

     

    Compliant Standards

    ISO 10101‑1:1993​ — Natural gas — Determination of water content — Part 1: Electrolytic method
    ISO 8573‑3:2019​ — Compressed air — Part 3: Test methods for measurement of dew point
    IEC 60079‑1​ — Explosive atmospheres — Part 1: Equipment protection by flameproof enclosures "d"(basis for Ex d IIB T4)
    GB/T 5832.1‑2011​ — Determination of trace moisture in gases — Part 1: Electrolytic method

     

    Key Features

    Ultra‑Low Dew Point Range:​ Measures from −90 °C Td to −6 °C Td, covering ultra‑dry gas applications such as pure nitrogen, hydrogen, and natural gas dehydration units.
    Exceptional Sensitivity:​ Detects moisture as low as 0.1 ppmv​ with accuracy of 0.1 ppmv or 1 % of measured value​ — ideal for stringent process control.
    Acid Gas Compatibility:​ Engineered to measure acidic and slightly corrosive gases​ that would damage standard capacitive or mirror‑based sensors.
    Explosion‑Proof Design:​ Certified Ex d IIB T4​ flameproof enclosure for safe operation in hazardous areas (Zone 1/Zone 2) with flammable gas atmospheres.
    Vaporization Chamber:​ Built‑in heated chamber (40 °C) ensures complete gasification of liquefied gases before measurement, preventing liquid carryover and sensor damage.
    Long‑Distance Networking:Meter Net​ capability allows monitoring of more than 100 meters​ of distributed analyzers from a single central computer running professional software.
    RS‑485 Communication:​ Standard Modbus RTU interface for seamless integration with plant DCS, PLC, or SCADA systems.
    Constant Temperature Control:​ Internal thermostat maintains stable sensor temperature under varying ambient conditions (−30 °C to 50 °C), ensuring consistent performance in outdoor or unconditioned installations.
    Sensor Over‑Range Protection:​ Automatic safety circuit prevents sensor damage if gas pressure or moisture exceeds safe limits.
    Professional Monitor Software:​ Displays real‑time data in curve form, stores all readings in a database, and enables remote device control​ from a central PC.
     

    Technical Specifications

    Name

    Parameter

    Name

    Parameter

    Dew point Range

    -90 ℃Td  -6 ℃Td

    Repeatability

    ≤±1 ℃Td

    Water content range

    0.1 ppmv3800 ppmv

    precision

    0.1 ppmv or 1% m.v.

    Flow rate

    100 sccm (adjustable)

    Response time

    5 min

    Gasification Temp.

    40

    Protection level

    IP65

    Communication

    RS 485

    Explosion-proof class

    EXDIIBT4

    connector

    1/8”meter pipe

    Gas pressure

    ≤1MPa

    Size (LⅩBⅩH)

    300Ⅹ120Ⅹ360 mm 

    Power supply

    AC220/110V 50/60Hz or DC24V

    Environment

    -30 ℃  50 ℃

     

     

     

     

    Application Industries & Scenarios

    Natural Gas & Oil & Gas

    Gas Dehydration Units:​ Monitor outlet dew point from glycol dehydrators or molecular sieve dryers to ensure pipeline specification compliance (ISO 10101‑1).
    Transmission Pipelines:​ Continuous dew point monitoring to prevent hydrate plugging and internal corrosion.
    LNG & LPG Plants:​ Verify dryness of process streams before liquefaction or fractionation.

    Petrochemical & Refining

    Hydrogen Production (SMR):​ Monitor moisture in high‑purity hydrogen recycle streams to protect catalysts and meet fuel cell vehicle specifications.
    Ethylene & Propylene Plants:​ Control trace water in monomer feedstocks to prevent polymerization issues.
    Sulfur Recovery Units:​ Measure moisture in acidic gas feeds (H₂S/CO₂) where standard sensors fail.

    Specialty Gas & Electronics

    Ultra‑High‑Purity (UHP) Gas:​ Online monitoring of nitrogen, oxygen, argon, and helium purity in semiconductor fabs.
    Bulk Gas Suppliers:​ Continuous certification of delivered gas quality at filling stations.

    Chemical & Pharmaceutical

    Moisture‑Sensitive Reactions:​ Monitor inert gas blanketing (nitrogen, argon) over reactors to ensure dry conditions.
    Polymerization Processes:​ Control water content in vinyl chloride, styrene, and other monomers.

    Compressed Air & Gas Distribution

    Instrument Air Systems:​ Verify dew point per ISO 8573‑3 for pneumatic controls and analytical instruments.
    Breathing Air Systems:​ Monitor moisture in compressed air for offshore platforms and diving operations.

     

    Frequently Asked Questions (FAQ)

    Q1: What is the difference between this online analyzer and the portable moisture meter?
    A: The portable meter​ is battery‑powered, handheld, and designed for spot‑checking, field service, and laboratory use. The online analyzer​ is a fixed‑installation device with an explosion‑proof enclosure (Ex d IIB T4), designed for continuous 24/7 monitoring​ in hazardous industrial areas. It offers RS‑485 networking, DCS integration, and a much lower dew point floor (−90 °C Td vs. −80 °C Td).
    Q2: What does "Ex d IIB T4" mean?
    A: Ex d​ indicates flameproof protection — the enclosure can withstand an internal explosion and prevent ignition of the surrounding atmosphere. IIB​ covers gas groups such as ethylene, propane, and town gas. T4​ means the maximum surface temperature does not exceed 135 °C, making it safe for environments with auto‑ignition temperatures above this level. This certification is essential for installation in Zone 1/Zone 2 hazardous areas.
    Q3: Can this instrument handle liquefied gases?
    A: Yes. The built‑in vaporization chamber​ heats the sample to 40 °C, ensuring complete gasification of liquefied gases (e.g., LPG, refrigerant gases) before they reach the sensor. This prevents liquid carryover that could damage the electrolytic cell.
    Q4: How far can the RS‑485 signal travel?
    A: RS‑485 communication can extend up to 1,200 meters (≈100 meters as noted in marketing materials, but technically up to 1.2 km with proper cabling). For longer distances, the professional monitor software supports networking of more than 100 meters of distributed analyzers​ from a single PC, enabling plant‑wide moisture monitoring.
    Q5: What is the advantage of the electrolytic method for acid gases?
    A: Most industrial moisture analyzers (capacitive, chilled mirror) use materials that degrade when exposed to acidic gases like H₂S, SO₂, or HCl. The P₂O₅ electrolytic sensor​ is chemically resistant to these environments, making it the preferred choice for sour gas, sulfur recovery, and acid gas injection applications.
    Q6: How is the sensor protected from over‑range conditions?
    A: The analyzer includes an automatic over‑range protection circuit​ that detects excessive gas pressure or abnormally high moisture levels and temporarily isolates or bypasses the sensor to prevent saturation or physical damage. An alarm is triggered to alert operators.
    Q7: Can the analyzer be powered by DC voltage?
    A: Yes. The instrument supports dual power options: AC 220/110V (50/60 Hz) for standard installations, or DC 24V​ for remote sites, solar‑powered systems, or integration with plant DC backup supplies.

     

     

  • Function:

    Perform on-line measurement of the dew point of non-corrosive gas and acid gas, or trace water content in the gas.

    Principle:

    The coil-like double platinum wire and its gap (less than 20um) constitute an electrolytic cell. Phosphorus pentoxide in the gap between platinum wires absorbs trace water to produce phosphoric acid and generates a weak current. The current is proportional to the amount of water absorbed. The dew point or trace water content is calculated according to the measured current.

  • StandardsGBT 5832.1

  • Characteristics:

    • High precision, 10 ppb.
    • Wide Test range, -80Td~-6 Td.
    • Corrosion resistance - It can measure acid gas and slightly corrosive gas.
    • The gasification chamber is used to heat the liquefied gas.
    • Sensor safety - with a sensor over range protection function.
    • Meter net - more than 100 meters can be monitored by a computer.
    • Explosion-proof class, ExdIIBT4.
    • With constant temperature function, it can be used stably under various climate conditions.
    • Provide an RS-485 port to connect to a computer.
    • Professional Monitor software - sample data showed in curve form, stored in the database. Real-time device control. 
  • Specification:

    Name

    Parameter

    Name

    Parameter

    Dew point Range

    -90 ℃Td  -6 ℃Td

    Repeatability

    ≤±1 ℃Td

    Water content range

    0.1 ppmv3800 ppmv

    precision

    0.1 ppmv1% m.v.

    Flow rate

    100 sccm (adjustable)

    Response time

    5 min

    Gasification Temp.

    40

    Protection level

    IP65

    Communication

    RS 485

    Explosion-proof class

    EXDIIBT4

    connector

    1/8”meter pipe

    Gas pressure

    ≤1MPa

    Size

    300Ⅹ120Ⅹ360 mm (LⅩBⅩH)

    Power supply

    AC220/110V 50/60Hz or DC24V

    Environment

    -30 ℃  50 ℃

     

     

     

Keywords:



Related Products


undefined

undefined

Product Consultation


Contact Us

Guangzhou Labstone Technology Co., Ltd
Add: Rm601, bldg A1, No. 2-6, Jinbao Rd, Baiyunhu Subdist., Baiyun District, Guangzhou,510430, Guangdong Province, P.R.China
Switchboard:+86(20)86406230  Technical:+86(20)86406337
 WhatsApp & Wechat:+86-13825027743
Email:market@labstone.cn 

Leave a Message to us

%{tishi_zhanwei}%

Copyright ©2026 Labstone Technology Co., Ltd  

business license