Key: test item, instrument name, total nonvolatile migration, gravimeter, moisture permeameter

%{tishi_zhanwei}%
undefined
+
  • undefined

Semi Automatical Sharpness Tester of Cutlery

STX-601
Focusing on packaging and material testing technology, we are committed to quality control in industries such as healthcare, pharmaceuticals, food, packaging, textiles, and new materials. Our products are widely used in enterprises, testing institutions, universities, and research institutes.
  • Description
  • Applications
  • Standard
  • Features
  • Parameter
  • Configuration
  • Video
  • PDF Download
    • Commodity name: Semi Automatical Sharpness Tester of Cutlery

    STX-601

    Medical Blades and Needles Sharpness Tester

     

    Function:

    Testing the sharpness and tip strength of medical blades and needles. 

    The primary purpose of a Medical Blades and Needles Sharpness Tester is to objectively and quantitatively measure the sharpness of surgical cutting instruments and needles. This process is a critical part of quality assurance in the manufacturing of medical devices.

    Quantitatively measure the sharpness of surgical cutting instruments and needles, including suture needles, acupuncture needles, and scalpel blades.
    Evaluate tip penetration force​ (piercing aluminum foil) and edge cutting force​ (slicing suture lines) to ensure consistent clinical performance.
    Determine the tip strength and resistance to bending or breaking​ under controlled compression.
    Essential for quality assurance, incoming inspection, and R&D​ in medical device manufacturing.

     

    Working Principle:

    The STX-601 medical blade and needle sharpness tester is a special device used for testing the sharpness and strength of various medical needles, including surgical suture needles and acupuncture needles. It uses the method of cutting medical suture lines to measure the sharpness of the needle edge, piercing aluminum foil to measure the sharpness of the needle tip, and pressing against a steel block to measure the strength of the medical needle. It consists of an intelligent controller, a force measuring mechanism, a large-screen LCD display, a printer, etc. The screen uses full Chinese display, and the cursor is controlled by the keyboard for options, operations, and settings. The operation is simple and convenient, with functions such as automatic positioning of cutting points and automatic speed adjustment. The test force curve of the needle is displayed in real time. Compliant.

     

    Compliant Standard:

    ISO 7864:2016​ - Sterile hypodermic needles for single use - Requirements and test methods(sharpness and tip strength)
    ASTM F2878-10(2018)​ - Standard Test Method for Hypodermic Needle Penetration Resistance
    ISO 9626:2016​ - Stainless steel needle tubing for the manufacture of medical devices(mechanical property reference)
    ISO 11608-2:2022​ - Needle-based injection systems - Part 2: Needles(performance requirements)

     

    Product Features:
     

    Ultra-High Precision:​ Force measurement error as low as 0.001 N​ with 0.5 accuracy grade​ and 50 Hz sampling speed, capturing even microscopic variations in cutting and penetration forces.
    Intelligent Automation:​ Automatic return, automatic positioning of blade/needle test points, and programmable speed adjustment ensure repeatable, operator-independent results.
    Real-Time Force Curve:​ Large LCD screen (320×240) displays the live force-displacement curve, allowing immediate visual assessment of sharpness and tip behavior.
    Multi-Mode Safety Protection:​ Multiple safety interlocks protect the operator and prevent damage to the force sensor during high-load compression tests.
    Group Testing & Statistics:​ Run multiple specimens and automatically calculate Max, Min, Average, and Standard Deviation. Results are printed via the built-in 57 mm micro-printer.
    Professional PC Software:​ Open database architecture allows unlimited storage, query, and customized report printing. Ideal for batch QC and audit trails.
    Versatile Speed Control:​ Stepless speed regulation from 0 to 350 mm/min​ adapts to different needle types, blade sizes, and international test protocols.

     

    Technical Specifications:

    Name

    Parameter

    Name

    Parameter

    Measurement Range

    10 N

    Accuracy Grade

    0.5 grade

    Resolution

    0.001N

    Test Speed

    0-350mm/min, stepless speed regulation

    Sampling Speed

    50 times/second

    Computer Software

    Yes

    Printer

    57mm miniature printer

    Screen Size

    320X240

    Host Size

    600×430×400 mm

    Host Net Weight

    35 Kg

    Power Supply

    AC220V50Hz, 200W

     

     

     

    Application Industries & Scenarios

    Surgical Suture Needles

    Edge Sharpness:​ Cut standardized suture lines to quantify the cutting force of taper-point, reverse-cutting, and blunt needles.
    Tip Penetration:​ Pierce aluminum foil to measure the initial puncture force of the needle tip.
    Tip Strength:​ Compress the needle tip against a steel block to determine resistance to bending or breakage during tissue penetration.

    Acupuncture & Traditional Chinese Medicine Needles

    Acupuncture Needle Sharpness:​ Evaluate the penetration force of filiform needles per YY 0166 and GB 2024.
    Shaft Straightness & Tip Integrity:​ Assess resistance to buckling under insertion simulation.

    Scalpels & Surgical Blades

    Blade Edge Sharpness:​ Measure the cutting force of No. 10, 11, 15 scalpel blades against standardized media.
    Blade-Tang Strength:​ Evaluate the bond between blade and handle under lateral or axial load.

    Hypodermic & Injection Needles

    Penetration Resistance:​ Test the force required to pierce synthetic membranes or biological simulants per ASTM F2878.
    Bevel Geometry Impact:​ Correlate tip grind angles with penetration force for process optimization.

    Medical Device R&D and QC

    New Product Development:​ Compare sharpness of prototype needles with market-leading competitors.
    Incoming Inspection:​ Screen batches of purchased needles for consistent sharpness before assembly.
    Regulatory Submission:​ Generate ISO 7864-compliant test reports for CE marking and FDA 510(k) filings.

     

    Frequently Asked Questions (FAQ)

    Q1: What is the difference between "sharpness" and "tip strength"?
    A: Sharpness​ refers to how easily the needle or blade penetrates or cuts material - measured by the cutting force​ (against suture lines) or penetration force​ (through foil). Tip strength​ is the maximum compressive force the tip can withstand before deforming or breaking - measured by pressing against a hardened steel block. Both are critical: a needle can be very sharp but too weak to penetrate tissue without bending.
    Q2: Which international standard should I reference?
    A: For hypodermic and suture needles, ISO 7864​ is the primary international standard. For penetration resistance testing, ASTM F2878​ is widely accepted, especially in North America. The STX-601 supports both methodologies and automatically calculates the required parameters.
    Q3: How does the automatic positioning feature work?
    A: The intelligent controller stores the coordinates of the test medium (suture line, foil, or steel block). After each test, the stage automatically returns to the home position and repositions for the next specimen, ensuring consistent contact point and eliminating manual alignment errors.
    Q4: Can this instrument test both needles and blades?
    A: Yes. With appropriate fixtures (included or optional), the same instrument tests suture needles, acupuncture needles, hypodermic needles, and surgical blades. The force range (0–10 N) and speed control (0–350 mm/min) are suitable for all these applications.
    Q5: What is the purpose of the real-time force curve?
    A: The live curve shows exactly how the force changes during cutting or penetration. This reveals not just the peak force, but also the force profile​ - whether the blade bites smoothly or jerks, whether the needle tip is symmetrical, and whether the cut is clean. This visual feedback is invaluable for R&D and failure analysis.
    Q6: Is the PC software required for basic operation?
    A: No. The instrument can operate fully standalone using the LCD screen and built-in printer for routine QC. The PC software is recommended for R&D, batch data management, and generating customized reports with statistical analysis.
    Q7: How often should the instrument be calibrated?
    A: We recommend calibration every 12 months or per your quality management system requirements. The instrument includes calibration weights and a self-diagnostic routine to verify sensor accuracy between formal calibrations.

     

     

Keywords:



Related Products


undefined

undefined

Product Consultation


Contact Us

Guangzhou Labstone Technology Co., Ltd
Add: Rm601, bldg A1, No. 2-6, Jinbao Rd, Baiyunhu Subdist., Baiyun District, Guangzhou,510430, Guangdong Province, P.R.China
Switchboard:+86(20)86406230  Technical:+86(20)86406337
 WhatsApp & Wechat:+86-13825027743
Email:market@labstone.cn 

Leave a Message to us

%{tishi_zhanwei}%

Copyright ©2026 Labstone Technology Co., Ltd  

business license