Key: test item, instrument name, total nonvolatile migration, gravimeter, moisture permeameter
Product
Determination of Overall Migration Constant Weight Analyzer
- Description
- Applications
- Standard
- Features
- Parameter
- Configuration
- Video
- PDF Download
-
- Commodity name: Determination of Overall Migration Constant Weight Analyzer
ERT-231 /462 -B
Automated Constant Weight Workstation — ETR Series
Functions
Perform constant weight tests for loss on drying, non-volatile substances, residue quantity, total migration, volatile substances, moisture content, and soluble/insoluble quantities.Replace traditional workflows — consolidate water baths, drying ovens, desiccators, and analytical balances into a single automated system.Eliminate manual sample transfers, reduce human error, and accelerate quality control for pharmaceutical, food, chemical, and polymer laboratories.Working Principle
The ETR Series integrates four critical processes into one enclosed unit: water bath evaporation, high-temperature drying, controlled cooling, and precision weighing.Evaporation: Samples in evaporating utensils are heated via a water bath (RT ~ 100 °C) to remove volatile solvents.Drying: The chamber temperature rises to 140 °C to drive off bound moisture and volatile matter.Cooling: Samples are cooled in a controlled-humidity environment (< 20 % RH) to prevent moisture reabsorption.Weighing: A METTLER TOLEDO analytical balance (0.1mg readability, optional 0.01mg) performs automated weighing. The system repeats drying-cooling-weighing cycles until constant weight (0.3 mg variation over 2 cycles) is achieved.All steps are controlled by professional software with programmable parameters, real-time monitoring, and automatic data logging.
Compliant Standards
USP <921> — Loss on Drying(United States Pharmacopeia)EP 2.2.32 — Loss on Drying(European Pharmacopoeia)ISO 759 — Plastics — Determination of loss of volatile matterISO 17025 — General requirements for the competence of testing and calibration laboratoriesChP 2025 — General Chapters: Loss on Drying, Total Solids, Extractives DeterminationYBB 00342002 / YBB 00132002 — Pharmaceutical packaging materials test methodsGB 31604.8 — Food contact materials — Total migrationGB 5009.3 — National food safety standard — Determination of moistureGB/T 9740 / GB/T 2914 — Chemical product loss on dryingKey Features
Fully Automated 4-Step Process: Water bath → Drying → Cooling → Weighing. No manual intervention required after sample loading.Ultra-High Precision: Achieves 0.3 mg constant weight in just 2 drying cycles using a METTLER TOLEDO balance (210 g capacity, 0.1 mg readability; 0.01 mg optional).Scalable Throughput: Available in 12, 18, 23, 33, 46, or 69 workstation configurations to match any lab's daily volume.Patented Balance Protection: Proprietary heat insulation, moisture-proof, and anti-corrosion technology shields the balance from thermal drift and chemical attack, ensuring long-term stability and extended service life.Indirect Heating Design: Prevents combustion and explosion risks. Equipped with over-temperature power-off and water-level protection for safe operation.Compact Integration: Combines water bath chamber, drying oven, cooling unit, and balance into a single footprint — saves valuable lab bench space.Dual Test Modes: Constant Weight Mode (auto-terminates at stable mass) and Constant Time Mode (fixed drying duration).Professional Software: Graphical, full-process monitoring with real-time curves, multi-factor data logging, and customizable report formats.GMP-Ready (Optional): Optional Computerized System module adds user management, access control, and audit trail for 21 CFR Part 11 compliance.Solvent Recovery (Optional): High-efficiency recovery unit captures up to 95 % of evaporated solvents, reducing hazardous waste disposal costs and VOC emissions.Technical Specifications
Name
Parameter
Name
Parameter
Constant Weighing Error
0.3 mg,(2 heating cycles)
Residue Range
0 ∼ 80g
Balance Range
210 g
Balance Readability
0.1mg
Temperature Error
0.5 ℃
Evaporation Temperature
RT ∼ 100 ℃
Drying Temperature
RT∼140 ℃
Weighing Temperature
RT ∼ 80 ℃
Evaporation Mode
Water bath
Weighing humidity
<20%
Evaporating utensil capacity
100 mL (Optional: 50, 200 mL)
Connection Pipe
Φ8 mm
Air Pressure
>0.3 MPa
Solvent Recovery Rate
Up to 95% (with optional unit)
Power Supply
AC220V /110V ;50/60Hz
Model
Model No
ERT-231-B
ERT-462-B
Specimen Capacity
23
46
Balance Quantity
1
2
Dimensions
1300x870x1160 mm(L*B*H)
Net Weight
≈ 175kg
≈ 185kg
Power Consumption
<10,000 W
Configuration: Principal Machine, Dryer Machine, Evaporating Utensil, Computer, Professional software, Valve Suits.
Optional: Solvent Recovery Machine、0.01mg balance.
Self-provided: Compressed air、Distilled water, tap water.
Application Industries & Scenarios
Pharmaceutical Industry
Loss on Drying & Moisture Content: Raw material QC per USP <921> and ChP.Total Migration & Extractables: Packaging material safety studies per YBB and EP.Stability Testing: Generate ICH Q1A/Q1B support data for drug substance and product registration.GMP Batch Release: Automated, audit-ready constant weight for routine batch release testing.Food & Beverage Industry
Food Contact Materials: Total migration testing per GB 31604 series and EU Framework Regulation.Moisture & Solids Determination: Nutritional labeling support per AOAC/ISO methods.Bottled Water & Beverages: Quality control per GB 8538 and ISO 7887.Shelf-Life Studies: Accelerated stability testing for formulation optimization.Chemicals & New Materials
Polymer Non-Volatile Residue: Determine solids content in resins, adhesives, and coatings.Raw Material Incoming Inspection: Verify supplier certificates of analysis.R&D Formulation: Screen drying parameters for new product development.Third-Party Testing & Research Institutes
CNAS/CMA-Compliant Services: Issue legally defensible reports referencing USP, EP, or ISO standards.Contract Research (CRO): High-throughput sample analysis for pharmaceutical clients.Method Development: Validate in-house procedures against official pharmacopoeia methods.Frequently Asked Questions (FAQ)
Q1: How does the ETR Series replace traditional lab workflows?A: It consolidates water bath evaporation, drying oven, desiccator cooling, and analytical weighing into a single automated system. This eliminates manual sample transfers between instruments, reduces human error, shortens testing cycles from days to hours, and improves reproducibility.Q2: Is the instrument suitable for GMP and pharmacopoeia-regulated labs?A: Yes. The ETR Series is engineered for regulated environments and complies with USP <921>, EP 2.2.32, and ChP loss-on-drying requirements. When equipped with the optional GMP module, it satisfies FDA 21 CFR Part 11 requirements for electronic records and signatures.Q3: Why is the patented balance protection important?A: Traditional balances degrade quickly when exposed to heat and humidity during drying processes. Our patented insulation, moisture-proof, and anti-corrosion design isolates the balance from harsh conditions, preserving 0.1 mg (or 0.01 mg) accuracy and significantly extending service life.Q4: Which model should I choose?A: Select based on throughput needs:ERT-231-B (23 stations): Ideal for QC labs with moderate daily workloads.ERT-462-B (46 stations): Best for high-volume testing, contract labs, and production environments.Custom 12–69 workstation configurations are also available upon request.Q5: Is the solvent recovery option worthwhile?A: Highly recommended. Recovering up to 95% of solvents sharply reduces hazardous waste disposal costs and lowers VOC emissions, delivering strong economic and environmental benefits for labs processing large numbers of samples.Q6: Can the system handle food-contact-material migration testing?A: Yes. The ETR Series fully supports GB 31604.8 and related international standards for total migration and residue determination in food packaging materials.Q7: What balance is included, and can it be upgraded?A: The standard configuration includes a METTLER TOLEDO analytical balance (210 g capacity, 0.1 mg readability). For ultra-trace applications, a 0.01 mg readability upgrade is available as an option. -
Functions
Constant weight tests for loss on drying, non - volatile substances, residue quantity, total migration, volatile substances, moisture content, soluble and insoluble quantities.
It can replace water baths, drying ovens and balances to achieve constant weight .
-
Standards:
Constant weighting requirement in Chinese Pharmacopoeia, Extractives Determination Method" in Part Four of the Chinese Pharmacopoeia、Loss on Drying Determination Method、Total Solids Determination Method、USP40-NF35<921>、YBB 00342002、YBB00132002、GB 31604.8、GB5009.3、GB 8538、DZT0064.9、GBT14415、GBT5750.4、GB/T 9740、GB/T2914、GB5413.39、ISO 759、"Purified Water" in Part Two of the Chinese Pharmacopoeia、EP9.0 WATER, PURIFIED
-
Features
- Complies with national standards and features a fully automated four-process system: water bath, drying, cooling, and weighing.
- Precise and efficient: Achieves 0.3mg constant weight with just 2 drying cycles. Available with 12、18, 23, 33, 46, or 69 workstations.
- Safe: Indirect heating design to prevent combustion and explosion. Equipped with over temperature power off protection and water level protection.
- Compact: Water bath chamber, drying oven, cooling unit and weighing balance are integrated into one unit, footprint reduction.
- Features patented: heat insulation, moisture proof, and anti-corrosion technology for the balance, ensuring its stability and long service life.
- Digitally set test parameters, fully automated operation without manual intervention. Offers two test modes: constant weight and constant time.
- Equipped with METTLER TOLEDO balance.
- Software: Provides graphical, full process and all element monitoring, along with multiple report formats.
- Optional: GMP "Computerized System" functional module.
- Optional: High - efficiency solvent recovery device.
- Complies with national standards and features a fully automated four-process system: water bath, drying, cooling, and weighing.
-
Specification
Name
Parameter
Name
Parameter
Constant Weighting Error
0.3 mg
(2 heating cycles)
Residue Range
0~80 g
Balance Range
210 g
Balance resolution
0.1 mg
Temperature Error
0.5 ℃
Evaporating Temperature
Room Temperature ~100 ℃
Drying Temperature
Room Temperature~140 ℃
Weighing Temperature
room~80 ℃
Evaporite Mode
Water bath
Weighing humidity
<20%
Evaporating utensil capacity
100 mL
(Optional: 50, 200 mL)
Connect Pipe
Φ8 mm
Air Pressure
>0.3 MPa
Solvent Recovery Rate
95% (Optional: Solvent Recovery Machine)
Power Supply
AC220V /110V ;50/60Hz
Model
Model
ERT-231-B
ERT-462-B
Specimen Count
23
46
Balance Count
1
2
Size (L×B×H) mm
1300x870x1160 mm
Net Weight
~175kg
~185kg
Power Consumption
<10,000 W
Keywords:
Next
Related Products
undefined
Product Consultation
Contact Us
Guangzhou Labstone Technology Co., Ltd
Add: Rm601, bldg A1, No. 2-6, Jinbao Rd, Baiyunhu Subdist., Baiyun District, Guangzhou,510430, Guangdong Province, P.R.China
Switchboard:+86(20)86406230 Technical:+86(20)86406337
WhatsApp & Wechat:+86-13825027743
Email:market@labstone.cn
Leave a Message to us
fOLLOW