Key: test item, instrument name, total nonvolatile migration, gravimeter, moisture permeameter
Product
6-Cavity Gas Permeation Tester-Differential Pressure Method
Focusing on packaging and material testing technology, we are committed to quality control in industries such as healthcare, pharmaceuticals, food, packaging, textiles, and new materials. Our products are widely used in enterprises, testing institutions, universities, and research institutes.
- 产品描述
-
- Commodity name: 6-Cavity Gas Permeation Tester-Differential Pressure Method
Gas Permeation Tester - Differential Pressure Method
6‑Cavity Parallel Oxygen / CO₂ / N₂ Transmission Tester
Overview
The LabStone BSG‑66‑G is a high‑throughput 6‑cavity gas permeation tester based on the differential pressure method. Designed for R&D and QC laboratories requiring rapid, precise barrier property characterization, it simultaneously measures the gas transmission rate (GTR), permeability coefficient, diffusion coefficient, and solubility coefficient of up to six distinct specimens.Fully compliant with ASTM D1434, ISO 15105‑1, JIS K7126‑A, and Chinese Pharmacopoeia standards, the BSG‑66‑G is the ideal solution for evaluating the barrier performance of high‑barrier films, laminates, metallized webs, and rigid packaging materials across pharmaceutical, food, electronics, and new energy industries.Key Applications
Pharmaceutical Packaging
Blister Pack Films: O₂ transmission rate (OTR) testing of PVC/PVDC, Aclar®, and cold‑form laminates for moisture‑ and oxygen‑sensitive APIs.Medical Device Pouches: CO₂ and N₂ permeability of Tyvek® and multilayer coextrusions.Regulatory Compliance: Pharmacopoeia‑mandated gas permeability testing for primary packaging materials (YBB 00082003).Food & Beverage Packaging
Modified Atmosphere Packaging (MAP): O₂ and CO₂ barrier evaluation of PA/PE, EVOH‑barrier, and PET films.Vacuum Packaging: Long‑term shelf‑life prediction based on O₂ ingress rates.High‑Barrier Laminates: Aluminum‑foil‑based structures for retort and aseptic packaging.Electronics & New Energy
Lithium‑Ion Battery Separators: O₂ and CO₂ permeability of PP/PE separators affecting battery safety and cycle life.Flexible Electronics: Barrier films for OLED encapsulation and thin‑film photovoltaics.Industrial & Specialty Films
Metalized Films: Pin‑hole and defect detection via gas permeation mapping.Rubber & Elastomers: Gas diffusion and solubility characterization for automotive and aerospace seals.Measured Parameters:
Gas Transmission Rate (GTR)Gas Permeability CoefficientDiffusion CoefficientSolubility CoefficientWorking Principle
The BSG‑66‑G employs the differential pressure method in accordance with ASTM D1434 and ISO 15105‑1:Specimen Mounting: Six test specimens are independently clamped between the high‑pressure chamber and low‑pressure chamber using a pneumatic clamping system. Each cavity is fully isolated.Dual‑Chamber Evacuation: Both high‑ and low‑pressure sides of all six cavities are simultaneously evacuated to a vacuum level below 10 Pa, ensuring complete removal of residual gases and adsorbed moisture.Pressure Differential Establishment: The low‑pressure side is isolated (sealed), while the high‑pressure side is charged with the test gas (O₂, CO₂, N₂, or other) to a preset pressure (0.1 - 0.2 MPa). A constant pressure differential is maintained throughout the test.Permeation Measurement: Gas molecules diffuse through the specimen from the high‑pressure side to the low‑pressure side. The rate of pressure increase in the low‑pressure chamber is precisely measured by a high‑accuracy vacuum sensor (0.1 Pa resolution).Data Calculation: The system calculates GTR, permeability, diffusion, and solubility coefficients based on the steady‑state pressure rise, specimen area, thickness, and temperature.
Compliance Standards:
ASTM D1434: Standard Test Method for Determining Gas Permeability Characteristics of Plastic Film and SheetingISO 15105‑1: Plastics - Film and sheeting - Determination of gas transmission rate - Part 1: Differential pressure methodISO 2556: Plastics - Determination of the gas transmission rate of films and thin sheets under atmospheric pressure - Manometric methodJIS K7126‑A: Testing method for gas permeability of plastic film and sheeting - Part A: Differential pressure methodChinese Pharmacopoeia (ChP) Vol. IV: Method for Determination of Gas PermeabilityYBB 00082003: Test method for gas permeability of laminated films for pharmaceutical packagingGB/T 1038: Plastics - Determination of gas permeability - Differential pressure methodKey Features
6‑Cavity Parallel TestingSix independent test stations allow simultaneous measurement of six different materials or six replicates of the same material, increasing throughput by up to 6× compared to single‑cavity instruments.High‑Precision Vacuum SensingEquipped with six independent imported high‑accuracy vacuum sensors (0.1 Pa resolution). Each cavity has dedicated sensing, eliminating cross‑interference and enabling independent test termination.Patented Baseline Subtraction TechnologyProprietary algorithm identifies and subtracts system background leakage, removing measurement bias caused by valve seals or piping permeation. This is critical for ultra‑high‑barrier materials (OTR < 0.01 cm³/m²·day).Pneumatic Specimen ClampingOne‑touch pneumatic clamping secures specimens in under 60 seconds. The system applies uniform pressure to prevent edge leakage while protecting delicate films from mechanical damage.Anti‑Side‑Leakage DesignPrecision‑machined sealing surfaces and optimized O‑ring geometry eliminate lateral leakage paths, ensuring that all measured gas flow originates from permeation through the specimen.Semiconductor Bidirectional Temperature ControlIntegrated thermoelectric (Peltier) heating and cooling provides precise temperature control from 15 - 50°C (±0.1°C) without compressors or refrigerants. Optional extended range (5 - 95°C) available.High‑Speed Vacuum SystemOptimized valve and piping design achieves < 10 Pa within 60 minutes. Rapid evacuation reduces total test time - high‑barrier films in < 24 h, medium/low‑barrier films in < 6 h.Environmentally IndependentBuilt‑in temperature control and stabilized pressure regulation mean the instrument does not require a constant‑temperature/humidity laboratory, significantly reducing facility costs.Intelligent DiagnosticsAutomatic self‑check at startup detects sensor faults, vacuum leaks, or abnormal pressure trends before testing begins, preventing wasted samples and time.GMP‑Ready (Optional)Optional Computerized System Module provides user management, role‑based access control, electronic signatures, and audit trails compliant with 21 CFR Part 11 and NMPA GMP.Dual‑Area Test Cells (Standard)Includes both 38.48 cm² (standard) and 7 cm² (small‑area) test cells, extending the measurable range from 0.01 to 2,500,000 cm³/m²·day·0.1MPa - covering everything from ultra‑barrier EVOH to porous membranes.Technical Specifications:
ParameterSpecificationMeasurement RangeLarge area (38.48 cm²): 0.01 - 500,000 cm³/m²·day·0.1MPa
Small area (7 cm²): 0.05 - 2,500,000 cm³/m²·day·0.1MPaTest Accuracy0.01 cm³/m²·day·0.1MPaVacuum Accuracy0.1 PaVacuum Range1333.33 PaFinal Vacuum Level< 10 Pa (attainable in ≤ 60 min)Temperature Range15 - 50 °C (5 - 95 °C optional)Temperature Accuracy±0.1 °C; uniformity ±0.5 °CTest Area38.48 cm² / 7 cm² (dual‑cell standard)Sample Thickness≤ 3 mmTest GasO₂, N₂, CO₂, and other non‑corrosive gasesGas Pressure (High Side)0.1 - 0.2 MPaSupply Gas Pressure0.1 - 0.8 MPa (user‑provided)Gas InterfaceΦ6 mmCalibration MethodStainless steel shim + certified reference film (2‑point calibration)Number of Test Stations6 (independent)Number of Vacuum Sensors6 (one per station)Clamping MethodPneumatic (automatic)Test DurationHigh‑barrier: < 24 h; Medium/Low‑barrier: < 6 hPower SupplyAC 220V, 50HzPower Consumption< 2000 WDimensions (L×B×H)700 × 740 × 470 mmNet WeightApprox. 130 kgStandard Configuration
- Main testing unit (BSG‑66‑G host)
- Vacuum pump
- Professional testing software
- Desktop computer
- Sample cutter
- Filter papers
- Vacuum bellows
- Gas cylinder regulator and fittings
- Vacuum grease
- Calibration kit (stainless steel shim + reference film)
Optional Accessories
- Container Test Fixtures (for finished packages)
- Extended Temperature Controller (5-95°C)
- Humidity Control Unit (for humidified gas testing)
- Tablet PC (for portable operation)
- GMP Computerized System Module
User‑Provided Items
- Test gas cylinders (O₂, CO₂, N₂, or other)
- Compressed air or nitrogen supply (> 0.8 MPa)
Frequently Asked Questions (FAQ)
Q1: What is the advantage of 6 independent cavities over a single‑cavity system?A: Six independent cavities allow you to test six different materials simultaneously or run six replicates of the same material in a single run. This is especially valuable for high‑barrier films, where a single test can take 24+ hours. A 6‑cavity system effectively multiplies your lab's throughput by sixfold.Q2: Can I test different gases in different cavities at the same time?A: All six cavities share a common gas inlet manifold, so they must be exposed to the same test gas during a single run. However, you can run O₂ in one batch, then CO₂ in the next, without recalibrating the instrument. For truly simultaneous multi‑gas testing, we recommend running sequential batches.Q3: What does "baseline subtraction technology" mean?A: Every permeation system has a small amount of background leakage through valves, seals, or piping. Our patented algorithm measures this baseline (with a stainless steel blank installed) and subtracts it from the sample signal. This is essential for accurately measuring ultra‑high‑barrier materials with OTR values below 0.1 cm³/m²·day.Q4: How long does it take to test a typical high‑barrier EVOH film?A: For a high‑barrier EVOH film (OTR ≈ 0.01-0.05 cm³/m²·day), expect 16-24 hours to reach steady state. Medium‑barrier films (e.g., nylon, PET) typically complete in 4-6 hours, while low‑barrier films (LDPE, EVA) finish in 1-2 hours.Q5: Do I need a constant‑temperature/humidity room for this instrument?A: No. The BSG‑66‑G has built‑in semiconductor temperature control (±0.1°C). As long as the lab ambient temperature stays within a reasonable range (10-35°C), the instrument maintains test chamber temperature independently. This saves significant capital expense on environmental chambers.Q6: Can this instrument test finished packages like bottles or blister packs?A: The standard BSG‑66‑G tests flat films and sheets. For finished containers, we offer optional container test fixtures that adapt the differential‑pressure method to bottles, blister packs, and trays. Please contact our technical team for details.Q7: What calibration is required?A: The instrument uses a 2‑point calibration: a stainless steel impermeable shim (for baseline subtraction) and a NIST‑traceable certified reference film (for sensitivity verification). Calibration is recommended annually or per your laboratory's quality system requirements.
Keywords:
Previous
Related Products
undefined
Product Consultation
Contact Us
Guangzhou Labstone Technology Co., Ltd
Add: Rm601, bldg A1, No. 2-6, Jinbao Rd, Baiyunhu Subdist., Baiyun District, Guangzhou,510430, Guangdong Province, P.R.China
Switchboard:+86(20)86406230 Technical:+86(20)86406337
WhatsApp & Wechat:+86-13825027743
Email:market@labstone.cn
Leave a Message to us
fOLLOW