Key: test item, instrument name, total nonvolatile migration, gravimeter, moisture permeameter

%{tishi_zhanwei}%
undefined
+
  • undefined

BSG-31J Gas Transmission Rate Tester

It is suitable for the detection of various gas permeability of O2, CO2, N2 and air of plastic film, composite film, high barrier material, sheet, metal foil, rubber and other materials.
Focusing on packaging and material testing technology, we are committed to quality control in industries such as healthcare, pharmaceuticals, food, packaging, textiles, and new materials. Our products are widely used in enterprises, testing institutions, universities, and research institutes.
  • Description
  • Applications
  • Standard
  • Features
  • Parameter
  • Configuration
  • Video
  • PDF Download
    • Commodity name: BSG-31J Gas Transmission Rate Tester
    • Commodity ID: BSG-31J

    It is suitable for the detection of various gas permeability of O2, CO2, N2 and air of plastic film, composite film, high barrier material, sheet, metal foil, rubber and other materials.

    Product Features

    It is suitable for the detection of various gas permeability of O2, CO2, N2 and air of plastic film, composite film, high barrier material, sheet, metal foil, rubber and other materials.

     

    working principle

    Using the principle design of the differential pressure method, the pre-treated sample is placed between the upper and lower test chambers, tightly sealed, and then the entire system is evacuated. When the required vacuum is reached, the lower chamber is closed and the high pressure chamber is closed. (Upper chamber) Fill with a certain amount of test gas and adjust the pressure of the upper chamber to maintain a constant pressure gradient difference between the two sides of the sample. Under the effect of the pressure gradient, the gas moves from the high pressure side (upper chamber) to the vacuum side (lower Cavity) penetration. Accurately measure the pressure change of the vacuum chamber (lower chamber) and calculate the various barrier parameters of the sample. Fully comply with GB1038, ASTM D1434 and other standards.

     

    Application characteristics

    Ÿ High-speed vacuum capability, reduced vacuum time, more thorough degassing, and high test accuracy;

    Ÿ Short test time and high efficiency;

    Ÿ Scalable test bottles and bags;

    Ÿ Power saving function;

    Ÿ The computer software fully complies with the requirements of GMP "Computerized System", and has functions such as user management, authority management, and data audit tracking.

    Ÿ Full monitoring and automatic recording, the test process can be reproduced throughout;

    Ÿ Powerful graph curve function, convenient for comparative testing and analysis;

    Ÿ Automatic test: set the test parameters, the test will be carried out automatically after the start, automatically judge the end of the test and save the test results;

    Ÿ The host software uses an encrypted general database system, data can be exported, and data storage, query, printing, etc. can be performed. Through the analysis of historical data, it is easy to grasp the historical dynamics of the product.

     

    Features

    Ÿ Imported high-precision vacuum sensor and pressure sensor;

    Ÿ Pure semiconductor bi-directional temperature control with heating and cooling, automatic control of temperature rise and temperature reduction, the temperature control range is wider and more precise; parallel operation, higher reliability;

    Ÿ The use of baseline technology to remove systematic errors, the test results are more accurate;

    Ÿ Possess accurate pressure control ability to maintain constant pressure difference;

    Ÿ Embedded system control, using high-quality components to ensure the stability and reliability of the instrument operation;

     

    Standards compliant

    Compatible with various test standards such as ISO and GB: YBB 00082003, GB 1038, ASTM D1434, ISO 2556, ISO 15105-1, JIS K7126-A

     

    Technical index

    Technical index

    technical parameter

     

    BSG-31J

     

    Measuring range (membrane)

    (cc/m2 · day · 0.1MPa)

    0.02-50,000

    Test accuracy

    0.01 cc/m2•day•0.1MPa

    Number of samples

    3

    Number of main sensors

    1

    Test mode

    Three-chamber mean

    Vacuum error

    0.1Pa

    Vacuum

    <10Pa

    Vacuum efficiency

    Within 20 minutes, below 27Pa;

    Test efficiency

    Test time <4 hours, when transmittance >5cc/m2.day.0.1MPa

    Temperature control range

    5℃-55℃(optional 90℃)

    Temperature control accuracy

    ±0.1℃

    Humidity range

    5~90 %RH (dual airflow humidity method, optional)

    Humidity accuracy

    ±1%RH

    test pressure

    0.1MPa~0.2Mpa

    Air pressure

    0.1MPa~0.8 MPa

    Test gas

    O 2 , N 2 , CO 2 or other gases

    Carrier gas interface

    ¢8

    Vacuum tube diameter

    1/4"

    Correction method

    Standard membrane calibration, external calibration of vacuum sensor

    Sample thickness

    ≤3mm

    Test area

    50cm 2 , round (other sizes can be customized)

    Host size

    (L×B×H)

    960×550×450mm

    Host weight (Kg)

    60Kg

    power supply

    220V AC 50HZ

     

    The standard configuration

    Serial number

    name

    Quantity

    model

    unit

    Remarks

    1

    Test host

    1

    BSG-31J

    station

    Included: vacuum sensor system, pressure sensor, gas circuit control system, environmental control system, communication system, display control system, etc.

    2

    High vacuum pump

    1

    VRD-4

    station

    Vacuum capacity: 2Pa

    3

    Professional testing software

    1

    GV series

    set

    1 Operating system requirements: Windows 2000 or XP or above;

    2Hardware requirements: 1G memory and 80G hard disk.

    4

    Communication Cable

    1

     

    root

    Standard RS232 communication line, length 2m

    5

    Vacuum steel pipe

    1.5

    1/4"

    Meter

    United States

    6

    Gas hose

    2

    Diameter 8mm

    Meter

     

    7

    Pressure reducing valve

    1

     

    only

     

    8

    Disc sampler-sample

    1

     

    set

    50cm2 sampler, cut the sample

    9

    Sealant

    1

     

    only

    Dow Corning

    10

    USB

    Conversion line

    1

     

    Article

    USB1.1 extension cable, 1m long.

    Matching

    Bottle bag test fixture

    1/3/3

     

    set

     

    Bring your own

    computer

    1

     

    set

    BSG-11A optional, standard for other models

    Test gas cylinder (oxygen etc.)

     

     

     

  • It is suitable for the detection of various gas permeability of O2, CO2, N2 and air of plastic film, composite film, high barrier material, sheet, metal foil, rubber and other materials.

  • Standards compliant

    Compatible with various test standards such as ISO and GB: YBB 00082003, GB 1038, ASTM D1434, ISO 2556, ISO 15105-1, JIS K7126-A

  • Application characteristics

    Ÿ High-speed vacuum capability, reduced vacuum time, more thorough degassing, and high test accuracy;

    Ÿ Short test time and high efficiency;

    Ÿ Scalable test bottles and bags;

    Ÿ Power saving function;

    Ÿ The computer software fully complies with the requirements of GMP "Computerized System", and has functions such as user management, authority management, and data audit tracking.

    Ÿ Full monitoring and automatic recording, the test process can be reproduced throughout;

    Ÿ Powerful graph curve function, convenient for comparative testing and analysis;

    Ÿ Automatic test: set the test parameters, the test will be carried out automatically after the start, automatically judge the end of the test and save the test results;

    Ÿ The host software uses an encrypted general database system, data can be exported, and data storage, query, printing, etc. can be performed. Through the analysis of historical data, it is easy to grasp the historical dynamics of the product.

     

    Features

    Ÿ Imported high-precision vacuum sensor and pressure sensor;

    Ÿ Pure semiconductor bi-directional temperature control with heating and cooling, automatic control of temperature rise and temperature reduction, the temperature control range is wider and more precise; parallel operation, higher reliability;

    Ÿ The use of baseline technology to remove systematic errors, the test results are more accurate;

    Ÿ Possess accurate pressure control ability to maintain constant pressure difference;

    Ÿ Embedded system control, using high-quality components to ensure the stability and reliability of the instrument operation;

  • Technical index

    Technical index

    technical parameter

     

    BSG-31J

     

    Measuring range (membrane)

    (cc/m2 · day · 0.1MPa)

    0.02-50,000

    Test accuracy

    0.01 cc/m2•day•0.1MPa

    Number of samples

    3

    Number of main sensors

    1

    Test mode

    Three-chamber mean

    Vacuum error

    0.1Pa

    Vacuum

    <10Pa

    Vacuum efficiency

    Within 20 minutes, below 27Pa;

    Test efficiency

    Test time <4 hours, when transmittance >5cc/m2.day.0.1MPa

    Temperature control range

    5℃-55℃(optional 90℃)

    Temperature control accuracy

    ±0.1℃

    Humidity range

    5~90 %RH (dual airflow humidity method, optional)

    Humidity accuracy

    ±1%RH

    test pressure

    0.1MPa~0.2Mpa

    Air pressure

    0.1MPa~0.8 MPa

    Test gas

    O 2 , N 2 , CO 2 or other gases

    Carrier gas interface

    ¢8

    Vacuum tube diameter

    1/4"

    Correction method

    Standard membrane calibration, external calibration of vacuum sensor

    Sample thickness

    ≤3mm

    Test area

    50cm 2 , round (other sizes can be customized)

    Host size

    (L×B×H)

    960×550×450mm

    Host weight (Kg)

    60Kg

    power supply

    220V AC 50HZ

     

  • The standard configuration

    Serial number

    name

    Quantity

    model

    unit

    Remarks

    1

    Test host

    1

    BSG-31J

    station

    Included: vacuum sensor system, pressure sensor, gas circuit control system, environmental control system, communication system, display control system, etc.

    2

    High vacuum pump

    1

    VRD-4

    station

    Vacuum capacity: 2Pa

    3

    Professional testing software

    1

    GV series

    set

    1 Operating system requirements: Windows 2000 or XP or above;

    2Hardware requirements: 1G memory and 80G hard disk.

    4

    Communication Cable

    1

     

    root

    Standard RS232 communication line, length 2m

    5

    Vacuum steel pipe

    1.5

    1/4"

    Meter

    United States

    6

    Gas hose

    2

    Diameter 8mm

    Meter

     

    7

    Pressure reducing valve

    1

     

    only

     

    8

    Disc sampler-sample

    1

     

    set

    50cm2 sampler, cut the sample

    9

    Sealant

    1

     

    only

    Dow Corning

    10

    USB

    Conversion line

    1

     

    Article

    USB1.1 extension cable, 1m long.

    Matching

    Bottle bag test fixture

    1/3/3

     

    set

     

    Bring your own

    computer

    1

     

    set

    BSG-11A optional, standard for other models

    Test gas cylinder (oxygen etc.)

     

     

     

Keywords: