Key: test item, instrument name, total nonvolatile migration, gravimeter, moisture permeameter

%{tishi_zhanwei}%
undefined
+
  • undefined

PSG-62 air permeability tester

It is suitable for the detection of O2, CO2, N2, air and other gas permeability of plastic film, composite film, high barrier material, sheet, metal foil, rubber and other materials. Compatible with ISO, GB and other test standards: YBB 00082003, GB/T 1038, ASTM D1434, ISO 2556, ISO 15105-1, JIS K7126-A
Focusing on packaging and material testing technology, we are committed to quality control in industries such as healthcare, pharmaceuticals, food, packaging, textiles, and new materials. Our products are widely used in enterprises, testing institutions, universities, and research institutes.
  • Description
  • Applications
  • Standard
  • Features
  • Parameter
  • Configuration
  • Video
  • PDF Download
    • Commodity name: PSG-62 air permeability tester
    • Commodity ID: PSG-62

    It is suitable for the detection of O2, CO2, N2, air and other gas permeability of plastic film, composite film, high barrier material, sheet, metal foil, rubber and other materials. Compatible with ISO, GB and other test standards: YBB 00082003, GB/T 1038, ASTM D1434, ISO 2556, ISO 15105-1, JIS K7126-A

    product description

    It is suitable for the detection of various gas permeability of O2, CO2, N2 and air of plastic film, composite film, high barrier material, sheet, metal foil, rubber and other materials.

     

    working principle

    Using the principle design of the differential pressure method, the pre-treated sample is placed between the upper and lower test chambers, tightly sealed, and then the entire system is evacuated. When the required vacuum is reached, the lower chamber is closed and the high pressure chamber is closed. (Upper chamber) Filled with a certain amount of test gas, and automatically adjust and maintain a constant pressure gradient difference on both sides of the sample. Under the effect of the pressure gradient, the gas moves from the high pressure side (upper chamber) to the vacuum side (lower chamber) penetration. Accurately measure the pressure change of the vacuum chamber (lower chamber) and calculate the various barrier parameters of the sample. Fully comply with GB1038, ASTM D1434 and other standards.

           

    Application characteristics

    Ÿ Extreme speed vacuum capability, reduce vacuum time, accelerate degassing and reduce test error;

    Ÿ Short test time and high efficiency;

    Ÿ Toxic gas can be measured without gas leakage;

    Ÿ Automatically adjust the test pressure to adapt to various pressure requirements;

    Ÿ Power saving function;

    Ÿ The computer software fully complies with the requirements of GMP "Computerized System", and has functions such as user management, authority management, and data audit tracking.

    Ÿ Full monitoring and real-time recording, the test process can be reproduced throughout;

    Ÿ Powerful graph curve function, convenient for comparative testing and analysis;

    Ÿ Automatic test: set the test parameters, the test will be carried out automatically after the start, automatically judge the end of the test and save the test results;

    Ÿ The host software uses an encrypted database system, data can be exported, and data storage, query, printing, and other functions can be performed. Through the analysis of historical data, it is easy to grasp the historical dynamics of the product.

     

    Features

    Ÿ Pure semiconductor bi-directional temperature control with heating and cooling, automatic control of temperature rise and temperature reduction, the temperature control range is wider and more precise; parallel operation, higher reliability;

    Ÿ The use of baseline technology to remove systematic errors, the test results are more accurate;

    Ÿ Possess accurate pressure control ability to maintain constant pressure difference;

    Ÿ International top vacuum sensors, high-quality components, and precision piping systems to ensure the stability and reliability of the instrument operation

    Ÿ Embedded system control, full computer control

     

    Adaptation standard

    Compatible with ISO, GB and other test standards: YBB 00082003, GB/T 1038, ASTM D1434, ISO 2556, ISO 15105-1, JIS K7126-A

    Technical index

    Technical index

    technical parameter

    PSG-62

    Measuring range

    (cc/m2/day/0.1MPa)

    0.01-10,000&

    0.05-100,000

    Test accuracy

    0.01 cc/m2/day/0.1MPa

    Number of samples

    6

    Number of main sensors

    2

    Test mode

    Two groups of three chambers

    Integration (mean)

    Vacuum error

    0.1Pa

    Vacuum capacity

    <10Pa

    Vacuum efficiency

    10 minutes, less than 27Pa;

    Temperature control range

    5℃-50℃; semiconductor bidirectional temperature control (optional water bath)

    Temperature control accuracy

    ±0.1℃

    Humidity range

    0%RH; 100%RH, 5~90%RH (dual airflow humidity method, optional)

    Humidity accuracy

    ±2%RH

    test pressure

    0.002MPa~0.2MPa

    Air pressure

    0.1 MPa~0.8 MPa

    Test gas

    O2, N2, CO2 or other gases

    Carrier gas interface

    ¢8

    Vacuum tube diameter

    ¢15

    Explicit control

    PC full control mode

    Correction method

    Baseline calibration, standard membrane calibration, external calibration of vacuum sensor

    Sample thickness

    ≤3mm

    Test area

    30cm2, round

    Host size

    (L×B×H) (mm)

    800×500×380

    Host weight

    (Kg)

    75Kg

    power supply

    220V AC 50HZ

     

    The standard configuration

    Serial number

    name

    Quantity

    model

    unit

    Remarks

    1

    Test host

    1

    PSG-62

    station

    Included: vacuum sensor system, pressure sensor, gas circuit control system, environmental control system, communication system, display control system, etc.

    2

    High vacuum pump

    1

    ND051

    station

    Vacuum capacity: 0.6 Pa

    3

    Professional testing software

    1

    PSG series

    set

    1 Operating system requirements: Windows 2000 or XP or above;

    2Hardware requirements: 1G memory and 80G hard disk.

    4

    Communication Cable

    1

     

    root

    Standard RS232 communication line, length 2m

    5

    Vacuum steel pipe

    1.5

    15mm

    Meter

     

    6

    Gas hose

    2

    Diameter 8mm

    Meter

     

    7

    Gas valve

    1

     

    only

     

    8

    Disc sampler-sample

    1

     

    set

    30C㎡ cut sample

    9

    Filter paper sampling plate

    1

     

    set

    Cut filter paper

    10

    Sealant

    1

     

    only

    Dow Corning

    11

    USB

    Conversion line

    1

     

    Article

    USB1.1 extension cable, 1m long.

    12

    computer

     

     

     

     

    Bring your own

    Test gas cylinder (oxygen etc.)

     

  • It is suitable for the detection of various gas permeability of O2, CO2, N2 and air of plastic film, composite film, high barrier material, sheet, metal foil, rubber and other materials.

  • Adaptation standard

    Compatible with ISO, GB and other test standards: YBB 00082003, GB/T 1038, ASTM D1434, ISO 2556, ISO 15105-1, JIS K7126-A

  • Application characteristics

    Ÿ Extreme speed vacuum capability, reduce vacuum time, accelerate degassing and reduce test error;

    Ÿ Short test time and high efficiency;

    Ÿ Toxic gas can be measured without gas leakage;

    Ÿ Automatically adjust the test pressure to adapt to various pressure requirements;

    Ÿ Power saving function;

    Ÿ The computer software fully complies with the requirements of GMP "Computerized System", and has functions such as user management, authority management, and data audit tracking.

    Ÿ Full monitoring and real-time recording, the test process can be reproduced throughout;

    Ÿ Powerful graph curve function, convenient for comparative testing and analysis;

    Ÿ Automatic test: set the test parameters, the test will be carried out automatically after the start, automatically judge the end of the test and save the test results;

    Ÿ The host software uses an encrypted database system, data can be exported, and data storage, query, printing, and other functions can be performed. Through the analysis of historical data, it is easy to grasp the historical dynamics of the product.

     

    Features

    Ÿ Pure semiconductor bi-directional temperature control with heating and cooling, automatic control of temperature rise and temperature reduction, the temperature control range is wider and more precise; parallel operation, higher reliability;

    Ÿ The use of baseline technology to remove systematic errors, the test results are more accurate;

    Ÿ Possess accurate pressure control ability to maintain constant pressure difference;

    Ÿ International top vacuum sensors, high-quality components, and precision piping systems to ensure the stability and reliability of the instrument operation

    Ÿ Embedded system control, full computer control

  • Technical index

    Technical index

    technical parameter

    PSG-62

    Measuring range

    (cc/m2/day/0.1MPa)

    0.01-10,000&

    0.05-100,000

    Test accuracy

    0.01 cc/m2/day/0.1MPa

    Number of samples

    6

    Number of main sensors

    2

    Test mode

    Two groups of three chambers

    Integration (mean)

    Vacuum error

    0.1Pa

    Vacuum capacity

    <10Pa

    Vacuum efficiency

    10 minutes, less than 27Pa;

    Temperature control range

    5℃-50℃; semiconductor bidirectional temperature control (optional water bath)

    Temperature control accuracy

    ±0.1℃

    Humidity range

    0%RH; 100%RH, 5~90%RH (dual airflow humidity method, optional)

    Humidity accuracy

    ±2%RH

    test pressure

    0.002MPa~0.2MPa

    Air pressure

    0.1 MPa~0.8 MPa

    Test gas

    O2, N2, CO2 or other gases

    Carrier gas interface

    ¢8

    Vacuum tube diameter

    ¢15

    Explicit control

    PC full control mode

    Correction method

    Baseline calibration, standard membrane calibration, external calibration of vacuum sensor

    Sample thickness

    ≤3mm

    Test area

    30cm2, round

    Host size

    (L×B×H) (mm)

    800×500×380

    Host weight

    (Kg)

    75Kg

    power supply

    220V AC 50HZ

     

  • The standard configuration

    Serial number

    name

    Quantity

    model

    unit

    Remarks

    1

    Test host

    1

    PSG-62

    station

    Included: vacuum sensor system, pressure sensor, gas circuit control system, environmental control system, communication system, display control system, etc.

    2

    High vacuum pump

    1

    ND051

    station

    Vacuum capacity: 0.6 Pa

    3

    Professional testing software

    1

    PSG series

    set

    1 Operating system requirements: Windows 2000 or XP or above;

    2Hardware requirements: 1G memory and 80G hard disk.

    4

    Communication Cable

    1

     

    root

    Standard RS232 communication line, length 2m

    5

    Vacuum steel pipe

    1.5

    15mm

    Meter

     

    6

    Gas hose

    2

    Diameter 8mm

    Meter

     

    7

    Gas valve

    1

     

    only

     

    8

    Disc sampler-sample

    1

     

    set

    30C㎡ cut sample

    9

    Filter paper sampling plate

    1

     

    set

    Cut filter paper

    10

    Sealant

    1

     

    only

    Dow Corning

    11

    USB

    Conversion line

    1

     

    Article

    USB1.1 extension cable, 1m long.

    12

    computer

     

     

     

     

    Bring your own

    Test gas cylinder (oxygen etc.)

     

Keywords: