Key: test item, instrument name, total nonvolatile migration, gravimeter, moisture permeameter

%{tishi_zhanwei}%
undefined
+
  • undefined

STG-V1 gas permeability tester

It is suitable for the detection of O2, CO2, N2, air and other gas permeability of plastic film, composite film, high barrier material, sheet, metal foil, rubber and other materials. Compatible with ISO, GB and other testing standards: YBB 00082003, GB/T 1038, ASTM D1434, ISO 2556, ISO 15105-1, JIS K7126-A.
Focusing on packaging and material testing technology, we are committed to quality control in industries such as healthcare, pharmaceuticals, food, packaging, textiles, and new materials. Our products are widely used in enterprises, testing institutions, universities, and research institutes.
  • Description
  • Applications
  • Standard
  • Features
  • Parameter
  • Configuration
  • Video
  • PDF Download
    • Commodity name: STG-V1 gas permeability tester
    • Commodity ID: STG-V1

    It is suitable for the detection of O2, CO2, N2, air and other gas permeability of plastic film, composite film, high barrier material, sheet, metal foil, rubber and other materials. Compatible with ISO, GB and other testing standards: YBB 00082003, GB/T 1038, ASTM D1434, ISO 2556, ISO 15105-1, JIS K7126-A.

    product description

    It is suitable for the detection of various gas permeability of O2, CO2, N2 and air of plastic film, composite film, high barrier material, sheet, metal foil, rubber and other materials.

     

    working principle

    Using the principle design of the differential pressure method, the pre-treated sample is placed between the upper and lower test chambers, tightly sealed, and then the entire system is evacuated. When the required vacuum is reached, the lower chamber is closed and the high pressure chamber is closed. (Upper chamber) Filled with a certain amount of test gas, and automatically adjust the pressure of the high-pressure chamber to maintain a constant pressure gradient difference between the two sides of the sample. Lower cavity) penetration. Accurately measure the pressure change of the vacuum chamber (lower chamber) and calculate the various barrier parameters of the sample. Fully comply with GB1038, ASTM D1434 and other standards.

     

    Application characteristics

    Ÿ High-speed vacuum capability, reduce vacuum time, accelerate degassing, and reduce test errors;

    Ÿ Short test time and high efficiency;

    Ÿ Expandable bottle and bag testing;

    Ÿ Power saving function;

    Ÿ Low gas consumption, one bottle of gas can be used continuously for 1 month;

    Ÿ The computer software fully complies with the requirements of GMP "Computerized System", and has functions such as user management, authority management, and data audit tracking.

    Ÿ Full monitoring, automatic recording, adjustable sampling rate; automatic repeat test;

    Ÿ The test process can be reproduced throughout; the powerful graphic curve function is convenient for comparative testing and analysis;

    Ÿ Fully automatic test: set the test parameters, the test will be performed automatically after the start, automatically judge the end of the test and save the test results;

    Ÿ The host software uses an encrypted general database system, data can be exported, and data storage, query, printing, etc. can be performed. Through the analysis of historical data, it is easy to grasp the historical dynamics of the product.

     

    Features

    Ÿ Pure semiconductor temperature control, automatic temperature control and temperature reduction, the temperature control range is wider and more accurate; parallel operation, higher reliability;

    Ÿ The use of baseline technology to remove systematic errors, the test results are more accurate;

    Ÿ Possess accurate pressure control ability to maintain constant pressure difference;

    Ÿ International top vacuum sensors, high-quality components, and precision piping systems to ensure the stability and reliability of the instrument operation

    Ÿ Embedded system control, large LCD screen display, dual control and dual operation of host and PC

     

    Technical index

    Technical index

    technical parameter

    STG-V1

    Measuring range

    (cc/m2•day•0.1MPa)

    0.05-100,000

    Test accuracy

    0.01 cc/m2•day•0.1MPa

    Number of samples

    1

    Number of main sensors

    1

    Test mode

    Single chamber independent

    Vacuum error

    0.1Pa

    Vacuum

    <10Pa

    Vacuum efficiency

    Within 10 minutes, below 27Pa; within 15 minutes, below 20Pa

    Test efficiency

    Test time <4 hours, when transmittance >5cc/m2.day.0.1MPa

    Temperature control range

    5℃-55℃ (optional 90℃)

    Temperature control accuracy

    ±0.1℃

    Humidity range

    5~90 %RH (dual airflow humidity method, optional)

    Humidity accuracy

    ±1%RH

    test pressure

    0.1MPa~0.2Mpa

    Air pressure

    0.1MPa~0.8MPa

    Test gas

    O 2 , N 2 , CO 2 or other gases

    Carrier gas interface

    ¢8

    Vacuum tube diameter

    ¢15

    Explicit control

    Real-time display of large LCD screen of test host, dual control mode of computer and test host

    Correction method

    Baseline calibration, standard membrane calibration, external calibration of vacuum sensor

    Sample thickness

    ≤3mm

    Test area

    50cm 2 , round (other sizes can be customized)

    Host size

    (L×B×H)

    585×640×430mm

    Host weight

    (Kg)

    40Kg

    power supply

    220V AC 50HZ

     

    System Configuration

    Serial number

    name

    Quantity

    model

    unit

    Remarks

    1

    Test host

    1

    STG-V1

    station

    STG-V1 type, including: vacuum sensor system, pressure sensor, gas circuit control system, environmental control system, communication system, display control system, etc.

    2

    High vacuum pump

    1

    ND051

    station

    Vacuum capacity: 0.6 Pa

    3

    Professional testing software

    1

    STG-V series

    set

    1 Operating system requirements: Windows 2000 or XP or above;

    2Hardware requirements: 1G memory and 80G hard disk.

    4

    Communication Cable

    1

     

    root

    Standard RS232 communication line, length 2m

    5

    Vacuum steel pipe

    1.5

    1/4"

    Meter

    American SWAGELOK

    6

    Gas hose

    2

    8mm

    Meter

     

    7

    Gas valve

    1

     

    only

     

    8

    Disc sampler-sample

    1

     

    set

    63cm2 sampler, cut the sample

    9

    Filter paper sampling plate

    1

     

    set

    49cm2 sampler, cut filter paper

    10

    Sealant

    1

     

    only

    Dow Corning

    11

    USB

    Conversion line

    1

     

    Article

    USB1.1 extension cable, 1m long.

    12

    computer

    1

    Lenovo Desktop

    station

    Standard

    Matching

    Bottle bag test fixture

    1/3/3

     

    set

     

    Bring your own

    Gas bottle

    (Oxygen etc.)

    1

    40L

    A

     

     

  • It is suitable for the detection of various gas permeability of O2, CO2, N2 and air of plastic film, composite film, high barrier material, sheet, metal foil, rubber and other materials.

  • Adaptation standard

    Compatible with ISO, GB and other test standards: YBB 00082003, GB/T 1038, ASTM D1434, ISO 2556, ISO 15105-1, JIS K7126-A.

  • Application characteristics

    Ÿ High-speed vacuum capability, reduce vacuum time, accelerate degassing, and reduce test errors;

    Ÿ Short test time and high efficiency;

    Ÿ Expandable bottle and bag testing;

    Ÿ Power saving function;

    Ÿ Low gas consumption, one bottle of gas can be used continuously for 1 month;

    Ÿ The computer software fully complies with the requirements of GMP "Computerized System", and has functions such as user management, authority management, and data audit tracking.

    Ÿ Full monitoring, automatic recording, adjustable sampling rate; automatic repeat test;

    Ÿ The test process can be reproduced throughout; the powerful graphic curve function is convenient for comparative testing and analysis;

    Ÿ Fully automatic test: set the test parameters, the test will be performed automatically after the start, automatically judge the end of the test and save the test results;

    Ÿ The host software uses an encrypted general database system, data can be exported, and data storage, query, printing, etc. can be performed. Through the analysis of historical data, it is easy to grasp the historical dynamics of the product.

     

    Features

    Ÿ Pure semiconductor temperature control, automatic temperature control and temperature reduction, the temperature control range is wider and more accurate; parallel operation, higher reliability;

    Ÿ The use of baseline technology to remove systematic errors, the test results are more accurate;

    Ÿ Possess accurate pressure control ability to maintain constant pressure difference;

    Ÿ International top vacuum sensors, high-quality components, and precision piping systems to ensure the stability and reliability of the instrument operation

    Ÿ Embedded system control, large LCD screen display, dual control and dual operation of host and PC

  • Technical index

    Technical index

    technical parameter

    STG-V1

    Measuring range

    (cc/m2•day•0.1MPa)

    0.05-100,000

    Test accuracy

    0.01 cc/m2•day•0.1MPa

    Number of samples

    1

    Number of main sensors

    1

    Test mode

    Single chamber independent

    Vacuum error

    0.1Pa

    Vacuum

    <10Pa

    Vacuum efficiency

    Within 10 minutes, below 27Pa; within 15 minutes, below 20Pa

    Test efficiency

    Test time <4 hours, when transmittance >5cc/m2.day.0.1MPa

    Temperature control range

    5℃-55℃ (optional 90℃)

    Temperature control accuracy

    ±0.1℃

    Humidity range

    5~90 %RH (dual airflow humidity method, optional)

    Humidity accuracy

    ±1%RH

    test pressure

    0.1MPa~0.2Mpa

    Air pressure

    0.1MPa~0.8MPa

    Test gas

    O 2 , N 2 , CO 2 or other gases

    Carrier gas interface

    ¢8

    Vacuum tube diameter

    ¢15

    Explicit control

    Real-time display of large LCD screen of test host, dual control mode of computer and test host

    Correction method

    Baseline calibration, standard membrane calibration, external calibration of vacuum sensor

    Sample thickness

    ≤3mm

    Test area

    50cm 2 , round (other sizes can be customized)

    Host size

    (L×B×H)

    585×640×430mm

    Host weight

    (Kg)

    40Kg

    power supply

    220V AC 50HZ

     

  • System Configuration

    Serial number

    name

    Quantity

    model

    unit

    Remarks

    1

    Test host

    1

    STG-V1

    station

    STG-V1 type, including: vacuum sensor system, pressure sensor, gas circuit control system, environmental control system, communication system, display control system, etc.

    2

    High vacuum pump

    1

    ND051

    station

    Vacuum capacity: 0.6 Pa

    3

    Professional testing software

    1

    STG-V series

    set

    1 Operating system requirements: Windows 2000 or XP or above;

    2Hardware requirements: 1G memory and 80G hard disk.

    4

    Communication Cable

    1

     

    root

    Standard RS232 communication line, length 2m

    5

    Vacuum steel pipe

    1.5

    1/4"

    Meter

    American SWAGELOK

    6

    Gas hose

    2

    8mm

    Meter

     

    7

    Gas valve

    1

     

    only

     

    8

    Disc sampler-sample

    1

     

    set

    63cm2 sampler, cut the sample

    9

    Filter paper sampling plate

    1

     

    set

    49cm2 sampler, cut filter paper

    10

    Sealant

    1

     

    only

    Dow Corning

    11

    USB

    Conversion line

    1

     

    Article

    USB1.1 extension cable, 1m long.

    12

    computer

    1

    Lenovo Desktop

    station

    Standard

    Matching

    Bottle bag test fixture

    1/3/3

     

    set

     

    Bring your own

    Gas bottle

    (Oxygen etc.)

    1

    40L

    A

     

     

Keywords:



Product Consultation